Accuracy of the new rapid test for monitoring adalimumab levels

Data de publicação:

Autores da FMUP

  • Claudia Camila Rodrigues Pereira Dias

    Autor

  • Fernando José Magro Dias

    Autor

Participantes de fora da FMUP

  • Rocha, C
  • Afonso, J
  • Lago, P
  • Arroja, B
  • Vieira, AI
  • Portuguese IBD Study Grp GEDII

Unidades de investigação

Abstract

Background: The loss of response to adalimumab (ADL) has been related to low serum concentrations at trough. Currently, most methods commercially available for the quantification of ADL are enzyme-linked immunosorbent assay (ELISA) based, with a turnaround time of approximately 8 h, delaying the target dosage adjustment to the subsequent infusion. In this study, we aimed to evaluate the performance of the newly available rapid-test ADL quantification assay by comparing it with three established ELISA methods, using spiked samples and a set of clinical samples. Methods: Spiked samples from control donors and 120 serum samples from inflammatory bowel disease (IBD) patients undergoing ADL therapy were quantified using lateral flow Quantum Blue (R) Adalimumab and, the ELISA formats from Immundiagnostik, R-Biopharm and an in-house assay. Results: The rapid-test assay had intraclass correlation coefficients of 0.590, 0.864 and 0.761 when comparing with the Immundiagnostik, R-Biopharm and in-house assays, respectively. For the five therapeutic windows, the accuracy was high: ADL rapid test compared with the Immundiagnostik (58-88%); R-Biopharm, 68-89%; and in house, 60-88%; and kappa statistics revealed 0.492-0.602, 0.531-0.659 and 0.545-0.682, respectively. Conclusions: The Quantum Blue (R) Adalimumab assay can replace the commonly used ELISA-based ADL quantification kits and it is a reliable alternative to these methods. This rapid-test assay enables the quantitative determination of ADL serum trough level in only 15 min. The developed assay allows measurement of ADL over a wide range. Hence, it represents a valuable tool for the clinician to assess the ADL trough level.

Dados da publicação

ISSN/ISSNe:
1756-283X, 1756-2848

Therapeutic Advances in Gastroenterology  SAGE Publications Ltd

Tipo:
Article
Páginas:
-
PubMed:
30833984
Link para outro recurso:
www.scopus.com

Citações Recebidas na Web of Science: 16

Citações Recebidas na Scopus: 16

Documentos

  • Não há documentos

Métricas

Filiações mostrar / ocultar

Keywords

  • adalimumab; Quantum Blue (R) Adalimumab; therapeutic drug monitoring

Citar a publicação