ATOMS (Adjustable Transobturator Male System) Is an Effective and Safe Second-Line Treatment Option for Recurrent Urinary Incontinence after Implantation of an AdVance/AdVance XP Fixed Male Sling? A Multicenter Cohort Analysis

Data de publicação: Data Ahead of Print:

Autores da FMUP

Participantes de fora da FMUP

  • Queissert, F
  • Rourke, K
  • Schönburg, S
  • Giammo, A
  • Gonsior, A
  • Gonzalez Enguita, C
  • Romero, A
  • Schrader, AJ
  • Martins, FE
  • Dorado, JF
  • Angulo, JC

Unidades de investigação

Abstract

(1) Background: This study examined outcomes of second-line ATOMS implantation after failure of the fixed male sling (FMS) AdVance/AdVance XP. (2) Methods: A retrospective multicenter cohort analysis was carried out in men implanted with an ATOMS between 2011 and 2020 after failure of an AdVance/AdVance XP. Success was assessed on the basis of objective (dryness, 0-1 pad/24 h or >20 g/24 h pad test) and subjective results (PGI-I). We performed the Wilcoxon rank sum test, Fisher's exact test, logistic regression, and multivariate analysis. (3) Results: The study included 88 patients from 9 centers with a mean age of 71.3 years. No Clavien-Dindo > II complications occurred within the first 3 months after ATOMS implantation. A total of 10 cases (9%) required revision in the ensuing clinical course. After a mean follow-up of 42.5 months, 76.1% achieved social continence, and 56.8% used no pads at all. Mean urine leakage/24 h dropped from 422 g (3.9 pads) to 38 g (0.69 pads) and the mean ICIQ-SF decreased from 16.25 to 5.3 (p < 0.0001). PROMs (patient-reported outcome measures) showed improvement in 98.9% of cases, and 63.6% gave a "very much better" PGI-I rating. Multivariate analysis identified a lower probability of achieving maximum satisfaction for the following factors: the AdVance XP as first-line therapy (OR 0.35), a lower ICIQ-SF question 1 (OR 0.26), status post-irradiation (OR 0.14), and more severe pain prior to ATOMS implantation (OR 0.51). (4) Conclusions: Implantation of an ATOMS is an effective and safe second-line treatment option for recurrent urinary incontinence after implantation of an AdVance/AdVance XP sling. High patient satisfaction was demonstrated in a long-term follow-up.

Dados da publicação

ISSN/ISSNe:
2077-0383, 2077-0383

Journal of Clinical Medicine  MDPI AG

Tipo:
Article
Páginas:
-
PubMed:
35011821
Link para outro recurso:
www.scopus.com

Citações Recebidas na Web of Science: 8

Citações Recebidas na Scopus: 8

Documentos

  • Não há documentos

Métricas

Filiações mostrar / ocultar

Keywords

  • adjustable transobturator male system; stress urinary incontinence; artificial urinary sphincter; fixed male sling; sling failure

Citar a publicação

Partilhar a publicação