Scleral Fixation of Akreos AO60 Intraocular Lens Using Gore-Tex Suture: An Eye on Visual Outcomes and Postoperative Complications

Autores da FMUP
Participantes de fora da FMUP
- Leuzinger Dias, M
- Lima Fontes, M
- Rodrigues, R
- Oliveira Ferreira, C
- Madeira, C
- Fernandes, V
Unidades de investigação
Abstract
Purpose. "In-the-bag" placement of an IOL is the Holy Grail for any cataract surgeon. However, in the absence of capsular integrity, alternative surgical options to place the IOL must be sought. We aim to report the clinical outcomes and safety profile of scleral-fixated Akreos AO60 intraocular lens implantation using Gore-Tex suture, combined with pars plana vitrectomy. Methods. This is a single-center, retrospective case series descriptive study. Electronic clinical records of all patients subjected to scleral fixation of a Bausch and Lomb Akreos AO60 IOL combined with pars plana vitrectomy, between April 1, 2017, and August 1, 2021, were reviewed. Data concerning age, sex, laterality, past ophthalmological history, pre- and postoperative best-available visual acuity, surgical indication, and intra- and postoperative complications were collected. Measured outcomes were the differences in best-available visual acuity and frequency of postoperative complications. Results. A total of 37 eyes (20 right eyes and 17 left eyes) from 36 patients (16 females and 20 males) were included in the statistical analysis. The mean age at time of surgery was 72.0 +/- 12.4 years. The mean follow-up period was 548.9 days (range 39-1564 days). Globally, the mean best-available logMAR visual acuity improved from 1.61 preoperatively (0.025 decimal equivalent) to 0.57 postoperatively (0.3 decimal equivalent), this difference being statistically significant (P < 0.001). Indications for surgery included aphakia due to complicated cataract surgery (24.3%; n = 9); subluxated IOL due to closed trauma (21.6%; n = 8); PEX-related subluxated IOL (16.2%; n = 6); non-traumatic, non-PEX-related subluxated IOL (18.9%; n = 7); subluxated crystalline lens due to closed trauma (8.1%; n = 3); aphakia due to open-globe injury (5.4%; n = 2); silicone-induced IOL opacification (2.7%; n = 1); and aphakia post-endophthalmitis (2.7%; n = 1). Postoperative complications included transient ocular hypertension (27.0%; n = 10), transient corneal edema (18.9%; n = 7), cystoid macular edema (18.9%, n = 7), self-limited hypotension (5.4%, n = 2), self-limited vitreous hemorrhage (2.7%, n = 1), central retinal vein occlusion (2.7%, n = 1), late retinal detachment (2.7%, n = 1), and Akreos IOL opacification (2.7%, n = 1). No suture-related complications were observed. Conclusion. There was a statistically significant improvement in visual acuity after scleral fixation of Akreos AO60 intraocular lens using Gore-Tex suture, with no suture-related problems recorded. This procedure seems to be a valuable alternative for posterior chamber IOL placement when secondary IOL implantation is required.
Dados da publicação
- ISSN/ISSNe:
- 2090-004X, 2090-0058
- Tipo:
- Article
- Páginas:
- 1-
- DOI:
- 10.1155/2021/9349323
- Link para outro recurso:
- www.scopus.com
Journal of Ophthalmology Hindawi Publishing Corporation
Citações Recebidas na Web of Science: 4
Citações Recebidas na Scopus: 6
Documentos
- Não há documentos
Filiações
Keywords
- IMPLANTATION
Campos de estudo
Proyectos asociados
Optical Coherence Tomography Angiography based prognostic factors for visual outcome after primary rhegmatogenous retinal detachment
Investigador Principal: Amândio António Rocha Dias de Sousa
Estudo Clínico Académico (Optical) . 2020
Evolução dos padrões epidemiológicos da prevalência de retinopatia diabética na diabetes mellitus tipo 1 entre 1990 e 2018: Estudo retrospetivo de uma população portuguesa
Investigador Principal: Manuel Alberto de Almeida e Sousa Falcão
Estudo Clínico Académico (Diabetes mellitus) . 2020
The influence of intensive near-work on refractive, biometric and topographic changes in last year Portuguese medical students: One-year longitudinal study
Investigador Principal: Manuel Alberto de Almeida e Sousa Falcão
Estudo Clínico Académico (near-work) . 2020
Prevalence and Area of Retinal Pigment Epithelium and Outer Retinal Atrophy in eyes with Non-Exudative Macular Neovascularization
Investigador Principal: Manuel Alberto de Almeida e Sousa Falcão
Estudo Clínico Académico . 2021
Long-Term Outcomes of Diabetic Macular Edema Treatment with Intravitreal Fluocinolone Acetonide: A Real-World Experience
Investigador Principal: Manuel Alberto de Almeida e Sousa Falcão
Estudo Clínico Académico (Diabetic Macular) . 2021
Endoftalmite após injeção intravítrea, cirurgia da catarata e vitrectomia pars plana: achados clínicos e outcomes visuais
Investigador Principal: Manuel Alberto de Almeida e Sousa Falcão
Estudo Clínico Académico . 2021
Current knowledge on treatment of endophthalmitis.
Investigador Principal: Manuel Alberto de Almeida e Sousa Falcão
Estudo Clínico Académico . 2020
Anterior chamber versus ciliary sulcus Ahmed glaucoma valve tube placement
Investigador Principal: Amândio António Rocha Dias de Sousa
Estudo Clínico Académico . 2021
Citar a publicação
Leuzinger M,Lima M,Rodrigues R,Oliveira C,Madeira C,Falcao F,Fernandes V,Rocha A,Falcao M. Scleral Fixation of Akreos AO60 Intraocular Lens Using Gore-Tex Suture: An Eye on Visual Outcomes and Postoperative Complications. J. Ophthalmol. 2021. 2021. p. 1-1. IF:1,974. (4).