Efficacy of near-infrared spectroscopy cerebral oximetry on detection of critical cerebral perfusion during carotid endarterectomy under regional anesthesia

Data de publicação:

Autores da FMUP

  • João Manuel Palmeira Rocha Neves

    Autor

  • Andre Filipe Mendes Leite Moreira

    Autor

  • José Pedro Oliveira Pinto

    Autor

  • Joana Irene De Barros Mourão

    Autor

  • José Paulo Alves Vieira De Andrade

    Autor

  • Ricardo Manuel De Pinto Vaz

    Autor

  • Armando Amilcar Pires Mansilha Rodrigues De Almeida

    Autor

Participantes de fora da FMUP

  • Pereira Macedo, J
  • Afonso, G

Unidades de investigação

Abstract

Background: Patients undergoing carotid endarterectomy (CEA) may suffer from cerebral hypoperfusion during the carotid cross-clamping. Near-infrared spectroscopy cerebral oximetry (NIRS) is a non-invasive method of regional cerebral oxygen saturation measurement reflecting charges in cerebral blood flow during CEA. The main goal of the study was to evaluate the accuracy of the NIRS in detecting cerebral hypoperfusior during CEA under regional anesthesia (RA) and compare it with awake neurological testing. Patients and methods: A prospective observational study of 28 patients that underwent CEA in RA and manifested neurologic deficits, and 28 consecutive controls from a tertiary and referral center, was performed. All patients were monitored with NIRS cerebral oximetry and awake testing as the control technique. Subsequently, operating characteristic curve and Coher's kappa coefficient were determined to evaluate the reliability of the monitoring test. Results: NIRS presented a sensitivity of 27.3% and a specificity of 89.3% in comparison to awake testing. Receiver operating characteristic (ROC) curve analysis demonstrated that a decrease of at least 20% in cerebral oxygen saturation is the best threshold to infer cerebral hypoperfusion. however, the respective area under the curve (AUROC) was 0.606 (95% CI: 0.456 -0.756, P = 0.178) with a calculated Cohen's kappa of 0.179, P = 0.093. Regarding 30-days outcomes, only awake testing has shown significant associations with stroke and postoperative complications (P = 0.043 and P = 0.05), which were higher in patients with post-clamping neurologic deficits. Conclusions: NIRS demonstrated a reduced discriminative capacity for critical cerebral hypoperfusion, and does not seem to add substantial clinical benefits to the awake test.

Dados da publicação

ISSN/ISSNe:
1664-2872, 0301-1526

VASA-EUROPEAN JOURNAL OF VASCULAR MEDICINE  Hogrefe Publishing

Tipo:
Article
Páginas:
367-374
PubMed:
32513067
Link para outro recurso:
www.scopus.com

Citações Recebidas na Web of Science: 8

Citações Recebidas na Scopus: 12

Documentos

  • Não há documentos

Métricas

Filiações mostrar / ocultar

Keywords

  • Carotid Stenosis; Carotid Endarterectomy; Cerebral Oximetry; Near-Infrared Spectroscopy; Neurologic Deficits

Citar a publicação

Partilhar a publicação