Reliability of point-of-care ultrasound for measuring quadriceps femoris muscle thickness

Data de publicação:

Autores da FMUP

  • Cristina Maria Nogueira Da Costa Santos

    Autor

  • Bernardo Manuel De Sousa Pinto

    Autor

Participantes de fora da FMUP

  • Pinto Ramos, J
  • Costa, F
  • Tavares, H
  • Cabral, J
  • Moreira, T
  • Brito, R
  • Barroso, J

Unidades de investigação

Abstract

BACKGROUND: Point-of-care ultrasound can be used to assess muscle thickness. However, its reliability has not been fully evaluated. AIM: This study aimed to assess the intrarater and inter-rater reliability of point-of-care ultrasound for the estimation of quadriceps and rectus femoris thickness in patients from a rehabilitation setting. DESIGN: This is a cross-sectional study. SETTING: This study was conducted at the Department of Physical Medicine and Rehabilitation of a tertiary care hospital. POPULATION: Twenty-nine inpatients consecutively selected after admission. METHODS: Four observers, two trained and two untrained, used point-of-care ultrasound to measure quadriceps femoris and rectus femoris thickness. Each observer performed two measurements followed by a second set of two measurements three hours later. Intraclass correlation coefficients (ICC) were then calculated. RESULTS: Both intrarater and inter-rater ICC were higher than 0.888 for both quadriceps and rectus femoris measurements. Reliability was high-est when ICC were calculated based on the average of two measurements, with the intrarater ICC being of 0.956 (95% CI: 0.937-0.970) for rectus femoris and of 0.966 (95% CI: 0.951-0.976) for quadriceps femoris; and with the inter-rater ICC being of 0.919 (95% CI: 0.863-0.957) for rectus femoris and 0.945 (95% CI: 0.907-0.971) for quadriceps femoris. Trained and untrained observers did not have significantly different ICC values. CONCLUSIONS: These results suggest that point-of-care ultrasound is a reliable option to measure muscle thickness of knee extensors by the same or different observers. CLINICAL REHABILITATION IMPACT: Measuring knee extensors thickness may aid to adequately modulate treatment choices in patients with disability. This study suggests that quadriceps and rectus femoris muscle thickness measured after a short training course, by either an experienced or inexperienced clinician, presents high reliability. Reliability can be increased if the average of two measurements is used. Be-sides being inexpensive and portable, point-of-care ultrasound is a reliable tool for measuring knee extensors thickness, rendering it potentially adequate to be used in clinical practice.

Dados da publicação

ISSN/ISSNe:
1973-9095, 1973-9087

European Journal of Physical and Rehabilitation Medicine  Edizioni Minerva Medica S.p.A.

Tipo:
Article
Páginas:
767-773
Link para outro recurso:
www.scopus.com

Citações Recebidas na Web of Science: 7

Citações Recebidas na Scopus: 7

Documentos

  • Não há documentos

Métricas

Filiações

Filiações não disponíveis

Keywords

  • KEY wo?ns; Quadriceps muscle; Validation study; Ultrasonography

Proyectos asociados

COVID-19: Monitorizar e planear com base no risco.

Investigador Principal: Cristina Maria Nogueira da Costa Santos

Estudo Observacional Académico (COVID-19) . 2020

Seroprevalence of SARS-CoV-2 and assessment of epidemiologic determinants in Portuguese municipal workers

Investigador Principal: Bernardo Manuel De Sousa Pinto

Estudo Clínico Académico (SARS-CoV-2) . 2021

Citar a publicação

Partilhar a publicação