Intraocular Pressure and Anterior Segment Morphometry Changes after Uneventful Phacoemulsification in Type 2 Diabetic and Nondiabetic Patients

Data de publicação:

Autores da FMUP

  • João Nuno Bicho Beato

    Autor

  • Angela Maria Veloso Guimarães Carneiro

    Autor

  • Fernando Manuel Mendes Falcão Reis

    Autor

Participantes de fora da FMUP

  • Reis, D
  • Esteves Leandro, J
  • Falc?o, M.
  • Rosas, V

Unidades de investigação

Abstract

Purpose. To compare intraocular pressure (IOP) and anterior segment (AS) morphometry changes after uneventful phacoemulsification between nonglaucomatous eyes with open-angles from patients with and without type 2 diabetes mellitus (DM) and determine which factors may predict greater IOP-lowering effect. Methods. Forty-five diabetic (45 eyes) and 44 (44 eyes) age- and sex-matched non-DM patients with age-related cataract were enrolled in this prospective observational study. Goldmann applanation tonometry and AS Scheimpflug tomography (Pentacam (R) HR) were performed preoperatively and at 1- and 6-month follow-up. Linear regression analysis was performed to evaluate the clinical variables related to postoperative IOP changes at 6months. Results. There was a significant postoperative IOP reduction 6months after surgery (p<0.001) by an average of 2.9 +/- 2.9mmHg (15.5%) and 2.4 +/- 2.8mmHg (13.0%) in the DM group and non-DM groups (p=0.410), respectively. All AS parameters (anterior chamber depth, volume, and angle) increased significantly postoperatively (p<0.001). Multivariate linear regression analysis showed that higher preoperative IOP was significantly associated with IOP reduction at 6-month follow-up (p<0.05). Conclusion. Nonglaucomatous eyes with open-angles from both type 2 diabetic and nondiabetic patients experienced similar AS changes and IOP reductions following uneventful phacoemulsification, and this IOP-lowering effect was strongly correlated with preoperative IOP.

Dados da publicação

ISSN/ISSNe:
2090-004X, 2090-0058

Journal of Ophthalmology  Hindawi Publishing Corporation

Tipo:
Article
Páginas:
1-
PubMed:
31281671
Link para outro recurso:
www.scopus.com

Citações Recebidas na Web of Science: 8

Citações Recebidas na Scopus: 10

Documentos

  • Não há documentos

Métricas

Filiações

Filiações não disponíveis

Keywords

  • CHAMBER DEPTH MEASUREMENT; LENS POSITION PARAMETERS; CATARACT-SURGERY; ANGLE WIDTH; REDUCTION; PENTACAM; EYES; IMPLANTATION; PREDICTORS; PRECISION

Partilhar a publicação