Deep complex convolutional network for fast reconstruction of 3D late gadolinium enhancement cardiac MRI

Data de publicação: Data Ahead of Print:

Autores da FMUP

  • Jennifer Mâncio Silva

    Autor

Participantes de fora da FMUP

  • El-Rewaidy, H
  • Neisius, U
  • Kucukseymen, S
  • Rodriguez, J
  • Paskavitz, A
  • Menze, B
  • Nezafat, R

Unidades de investigação

Abstract

Several deep-learning models have been proposed to shorten MRI scan time. Prior deep-learning models that utilize real-valued kernels have limited capability to learn rich representations of complex MRI data. In this work, we utilize a complex-valued convolutional network (DOUBLE-STRUCK CAPITAL CNet) for fast reconstruction of highly under-sampled MRI data and evaluate its ability to rapidly reconstruct 3D late gadolinium enhancement (LGE) data. DOUBLE-STRUCK CAPITAL CNet preserves the complex nature and optimal combination of real and imaginary components of MRI data throughout the reconstruction process by utilizing complex-valued convolution, novel radial batch normalization, and complex activation function layers in a U-Net architecture. A prospectively under-sampled 3D LGE cardiac MRI dataset of 219 patients (17 003 images) at acceleration rates R = 3 through R = 5 was used to evaluate DOUBLE-STRUCK CAPITAL CNet. The dataset was further retrospectively under-sampled to a maximum of R = 8 to simulate higher acceleration rates. We created three reconstructions of the 3D LGE dataset using (1) DOUBLE-STRUCK CAPITAL CNet, (2) a compressed-sensing-based low-dimensional-structure self-learning and thresholding algorithm (LOST), and (3) a real-valued U-Net (realNet) with the same number of parameters as DOUBLE-STRUCK CAPITAL CNet. LOST-reconstructed data were considered the reference for training and evaluation of all models. The reconstructed images were quantitatively evaluated using mean-squared error (MSE) and the structural similarity index measure (SSIM), and subjectively evaluated by three independent readers. Quantitatively, DOUBLE-STRUCK CAPITAL CNet-reconstructed images had significantly improved MSE and SSIM values compared with realNet (MSE, 0.077 versus 0.091; SSIM, 0.876 versus 0.733, respectively; p < 0.01). Subjective quality assessment showed that DOUBLE-STRUCK CAPITAL CNet-reconstructed image quality was similar to that of compressed sensing and significantly better than that of realNet. DOUBLE-STRUCK CAPITAL CNet reconstruction was also more than 300 times faster than compressed sensing. Retrospective under-sampled images demonstrate the potential of DOUBLE-STRUCK CAPITAL CNet at higher acceleration rates. DOUBLE-STRUCK CAPITAL CNet enables fast reconstruction of highly accelerated 3D MRI with superior performance to real-valued networks, and achieves faster reconstruction than compressed sensing.

Dados da publicação

ISSN/ISSNe:
1099-1492, 0952-3480

NMR in Biomedicine  John Wiley and Sons Ltd

Tipo:
Article
Páginas:
-
PubMed:
32352197

Citações Recebidas na Web of Science: 43

Citações Recebidas na Scopus: 47

Documentos

  • Não há documentos

Métricas

Filiações mostrar / ocultar

Keywords

  • complex convolutional network; deep learning; image reconstruction; late gadolinium enhancement; MRI

Citar a publicação

Partilhar a publicação