Immunomagnetic bead-based bioassay for the voltammetric analysis of the breast cancer biomarker HER2-ECD and tumour cells using quantum dots as detection labels
Autores da FMUP
Participantes de fora da FMUP
- Freitas, M
- Nouws, HPA
- Fernandes, VC
- Delerue Matos, C
Unidades de investigação
Abstract
An electrochemical magnetic immunosensing strategy was developed for the determination of HER2-ECD, a breast cancer biomarker, and breast cancer cells in human serum. A sandwich assay was performed on carboxylic acid-functionalized magnetic beads (MBs) using a screen-printed carbon electrode (SPCE) as transducer surface. The affinity process was detected using electroactive labels; core/shell streptavidin-modified CdSe@ZnS Quantum Dots (QDs). Cd2+ ions, released from the QDs, were determined by differential pulse anodic stripping voltammetry (DPASV). An assay time of 90 min, with an actual hands-on time of about 20 min, a linear range between 0.50-50 ng center dot mL(-1) of HER2-ECD and a limit of detection of 0.29 ng center dot mL(-1) were achieved. Analysis of live breast cancer cells was also performed using the optimized assay. Breast cancer cell lines SK-BR-3 (a HER2-positive cell line), MDA-MB-231 (a HER2-negative cell line) and MCF-7 (a cell line with low HER2 expression) were tested. The selectivity of the assay towards SK-BR-3 cells was confirmed. A concentration-dependent signal that was 12.5x higher than the signal obtained for the HER2-negative cells (MDA-MB-231) and a limit of detection of 2 cells center dot mL(-1) was obtained. Schematic representation of the electrochemical immunomagnetic assay for the determination of the breast cancer biomarker HER2-ECD and cancer cells using magnetic beads (MBs), a screen-printed carbon electrode (SPCE) as transducer surface and quantum dots (QD) as electroactive labels.
Dados da publicação
- ISSN/ISSNe:
- 1436-5073, 0026-3672
- Tipo:
- Article
- Páginas:
- 184-
- PubMed:
- 32088788
- Link para outro recurso:
- www.scopus.com
MICROCHIMICA ACTA Springer-Verlag Wien
Citações Recebidas na Web of Science: 47
Citações Recebidas na Scopus: 48
Documentos
- Não há documentos
Filiações
Keywords
- Breast cancer; Cancer cells; Electrochemical immunoassay; HER2-ECD; Magnetic beads; Quantum dots
Citar a publicação
Freitas M,Nouws H,Keating E,Fernandes VC,Delerue C. Immunomagnetic bead-based bioassay for the voltammetric analysis of the breast cancer biomarker HER2-ECD and tumour cells using quantum dots as detection labels. Mikrochim Acta. 2020. 187. (3):p. 184-184. IF:5,833. (1).
Portal de investigação