Anterior Chamber Versus Ciliary Sulcus Ahmed Glaucoma Valve Tube Placement: Longitudinal Evaluation of Corneal Endothelial Cell Profiles
Autores da FMUP
Participantes de fora da FMUP
- Godinho, G
- Oliveira Ferreira, C
- Madeira, C
- Estrela Silva, S
Unidades de investigação
Abstract
Precis: An Ahmed glaucoma valve (AGV) tube in the ciliary sulcus (CS) is safer for the endothelium. At 4 years of follow-up, there was a significant decrease in endothelial cell count only with anterior chamber (AC) placement. Purpose: Corneal endothelium (CE) damage is one of the most feared long-term complications that can result from glaucoma drainage devices. Nonetheless, there is a lack of studies evaluating longitudinal changes in CE cells. This study aims to compare CE changes after AGV implantation in eyes with AC or CS tube placement. Materials and Methods: This was a retrospective, nonrandomized, longitudinal study of pseudophakic eyes with open-angle glaucoma and medically uncontrolled intraocular pressure that received an AGV. Eyes with additional glaucoma surgeries performed during follow-up were excluded. The main outcome measure was endothelial cell density (ECD), which was evaluated 1 year +/- 2 months and 4 years +/- 2 months postoperatively. The average endothelial cell size (AS) and the distance from the tube tip to the cornea were also evaluated. Results: Twenty-six eyes from 26 patients, with a mean age of 73 +/- 10 years, were included. The tube was placed in the AC in 15 eyes and in the CS in 11 eyes. The eyes with tube placement in the AC showed a significant AS increase (P=0.007) and ECD decrease (P=0.034), whereas eyes with tube placement in the CS had no significant AS (P=0.575) or ECD (P=0.445) change. In the eyes with tube placement in the AC, there was no correlation between DTC and ECD (P=0.260) or AS (P=0.428) changes. Conclusions: Tube placement in the AC seems to lead to significant CE cell loss over time, compared with tube placement in the CS.
Dados da publicação
- ISSN/ISSNe:
- 1057-0829, 1536-481X
- Tipo:
- Article
- Páginas:
- 170-174
- PubMed:
- 33955946
- Link para outro recurso:
- www.scopus.com
Journal of Glaucoma Lippincott Williams and Wilkins Ltd.
Citações Recebidas na Web of Science: 16
Citações Recebidas na Scopus: 19
Documentos
- Não há documentos
Filiações
Keywords
- corneal endothelium; Ahmed glaucoma valve; long-tube shunts; ciliary sulcus; anterior chamber
Citar a publicação
Godinho G,Barbosa J,Oliveira C,Madeira C,Melo A,Falcao F,Estrela S. Anterior Chamber Versus Ciliary Sulcus Ahmed Glaucoma Valve Tube Placement: Longitudinal Evaluation of Corneal Endothelial Cell Profiles. J. Glaucoma. 2021. 30. (2):p. 170-174. IF:2,290. (3).
Portal de investigação
