Outcomes of Low and Standard-Profile Fenestrated and Branched Stent-Grafts for Treatment of Complex Abdominal and Thoracoabdominal Aortic Aneurysms
Autores da FMUP
Participantes de fora da FMUP
- Tenorio, ER
- Barbosa Lima, GB
- Baghbani-Oskouei, A
- Saquib, N
- Mendes, BC
- Mirza, AK
- Oderich, GS
Unidades de investigação
Abstract
Objective: We compared the outcomes of fenestrated-branched (FB) endovascular abdominal aortic aneurysm repair (EVAR) using low-profile (LP) and standard-profile (SP) stent grafts for the treatment of complex abdominal aortic aneurysms (CAAAs) and thoracoabdominal aortic aneurysms (TAAAs). Methods: We reviewed the clinical data of 466 consecutive patients (70% male; mean age, 74 +/- 8 years) enrolled in a prospective nonrandomized study to investigate FB-EVAR for the treatment of CAAAs and TAAAs (2013-2021). The endpoints compared between the patients treated with LP (18F-20F) and SP (20F-22F) devices included procedural metrics, access-related complications, major adverse events (MAE), patient survival, freedom from secondary intervention, thromboembolic events, stent graft integrity issues, aneurysm sac enlargement, and the rate of sac shrinkage. Results: Of the 466 aneurysms treated by FB-EVAR, 138 were CAAAs and 141 were extent IV and 187 extent I to III TAAAs, with a mean number of 3.9 +/- 0.5 vessels stented per patient. LP devices had been used in 239 patients (51%) and SP devices in 227 patients (49%). LP devices had been used more frequently for chronic dissections (12% vs 7%; P = .041) and with preloaded systems (77% vs 65%; P = .005) and bilateral percutaneous femoral access (83% vs 74%; P = .020) and less frequently with upper extremity access (67% vs 88%; P < .001) and iliac conduits (2% vs 6%; P = .020). The patients treated using LP devices had experienced similar technical success (96% vs 97%; P = .527), with a shorter total operating time (225 +/- 81 minutes vs 243 +/- 78 minutes; P = .018), lower radiation exposure (median, 0.93 Gy; interquartile range [IQR], 0.94; vs median, 1.01 Gy; IQR, 0.91 Gy; P < .001), and less use of contrast (median, 135 mL; IQR, 68 mL; vs median, 144 mL; IQR, 80 mL; P = .008). No differences were found in the rates of iliofemoral access complications between the LP and SP device groups (1.3% vs 3.5%; P = .107). At 30 days, 5 patients had died (1%) and MAEs had occurred in 89 patients (19%), with no differences between the two groups. The mean follow-up was 28 months (95% confidence interval, 25-30 months). At 4 years, the patients treated with LP devices had had similar freedom from all-cause mortality (69% +/- 6% vs 68% +/- 4%; P = .199), freedom from aortic-related mortality (97% +/- 1% vs 98% +/- 1%; P = .488), freedom from any secondary intervention (65% +/- 6% vs 70% +/- 4%; P = .433), freedom from thromboembolic events (98% +/- 1% vs 99% +/- 1%; P = .364) and aneurysm sac enlargement (93% +/- 3% vs 91% +/- 3%; P = .293). However, the LP group had had less freedom from any integrity-related issues (92% +/- 5% vs 100%; P < .001). The cumulative risk of sac shrinkage was greater for patients treated with LP devices (adjusted hazard ratio, 2.040; 95% confidence interval, 1.516-2.744; P < .001). Conclusions: FB-EVAR was performed with low rates of mortality and MAEs, irrespective of the device profile. However, the procedures performed with LP devices had had less need for iliac conduits and had had better procedural metrics. The use of LP devices resulted in higher rates of sac shrinkage. However, the results on stent graft integrity require future investigation.
Dados da publicação
- ISSN/ISSNe:
- 1097-6809, 0741-5214
- Tipo:
- Article
- Páginas:
- 1160-1160
- Link para outro recurso:
- www.scopus.com
Journal of Vascular Surgery Mosby Inc.
Citações Recebidas na Web of Science: 6
Citações Recebidas na Scopus: 8
Documentos
- Não há documentos
Filiações
Filiações não disponíveis
Keywords
- Branched endograft; Fenestrated endograft; Low-profile endograft; Standard-profile endograft; Thoracoabdominal aortic aneurysm
Proyectos asociados
Red blood cell distribution width predicts myocardial infarction and mortality after vascular surgery - A prospective cohort study
Investigador Principal: Marina Felicidade Dias Neto
Estudo Clínico Académico (Red blood) . 2021
Secondary intervention and surveillance after abdominal aortic aneurysm repair: retrospective cohort study
Investigador Principal: Marina Felicidade Dias Neto
Estudo Clínico Académico (Aortic aneurysm) . 2022
High-dependency unit care after carotid endarterectomy for asymptomatic stenosis
Investigador Principal: Marina Felicidade Dias Neto
Estudo Clínico Académico . 2020
Recurrence of Varicose Veins After Surgery
Investigador Principal: Marina Felicidade Dias Neto
Estudo Clínico Académico . 2022
Radiomics Signature of Abdominal Aortic Aneurysm Neck: A Cross-Sectional Study
Investigador Principal: Marina Felicidade Dias Neto
Estudo Clínico Académico . 2022
ABO-blood groups and outcomes after abdominal aortic aneurysm repair
Investigador Principal: Marina Felicidade Dias Neto
Estudo Clínico Académico . 2022
Citar a publicação
Dias M,Tenorio ER,Barbosa GB,Baghbani A,Saquib N,Mendes BC,Mirza AK,Oderich GS. Outcomes of Low and Standard-Profile Fenestrated and Branched Stent-Grafts for Treatment of Complex Abdominal and Thoracoabdominal Aortic Aneurysms. J. Vasc. Surg. 2022. 76. (5):p. 1160-1160. IF:4,300. (1).