Implementing ICHOM standard set for cataract surgery at IPO-Porto (Portugal): clinical outcomes, quality of life and costs
Data de publicação:
Autores da FMUP
Participantes de fora da FMUP
- Queir?s, L
- Redondo, P
- França, M
- Silva, SE
- Borges, P
- de Melo, AB
- Pereira, N
- da Costa, PF
- Carvalho, N
- Borges, M
- Sequeira, I
- Lemos, J
Unidades de investigação
Abstract
Background: This paper fills a gap in the applied research field, for a local context, by addressing the topics of describing cataract surgery? clinical outcomes; quality of life (QoL); and costs of the patients treated after the implementation of the ICHOM standard set. Methods: This is a retrospective observational study using real-world data (RWD). We included all patients subjected to cataract surgery at the Portuguese Institute of oncology - Porto (IPO-Porto), Portugal, after 3?months follow up period completed between 5th June 2017 and 21st May 2018. The following inclusion criteria: corrected visual acuity of ? 6/10 or other significant visual disturbance due to lens opacity or the existence of a large anisometropia. A circuit was implemented based on the ICHOM standard for cataract, to measure clinical variables (e.g. visual acuity) and QoL (CATQUEST-9SF) before and after surgery, and cost of treatment. The results were explored by means of a paired-sample t-test, considering normality assumptions. Results: Data refers to 268 patients (73 P25-P75:32?95 years old), regarding 374 eyes. The cataract surgery had a positive effect on visual acuity (p < 0.001), refraction (right and left cylinder; p <?0.001) and all QoL dimensions. The vast majority of patients, around 98%, reported improvements in QoL. Based on IPO-Porto administrative records, the direct cost of treating cataracts (per eye) is of 500?, representing a total cost of 187,000? for the number of patients operated herein. Conclusion: This study reports the successful implementation of the ICHOM standard set for cataracts in a Portuguese institution and confirms that cataract surgery provides a rapid visual recovery, with excellent visual outcomes and minimal complications in most patients, while also having a positive impact on patients? quality of life. ? 2021, The Author(s).
Dados da publicação
- ISSN/ISSNe:
- 1471-2415, 1471-2415
- Tipo:
- Article
- Páginas:
- -
- PubMed:
- 33673817
- Link para outro recurso:
- www.scopus.com
BMC Ophthalmology BioMed Central Ltd.
Citações Recebidas na Web of Science: 11
Citações Recebidas na Scopus: 11
Documentos
- Não há documentos
Filiações
Filiações não disponíveis
Keywords
- Outcomes assessment; Ophthalmology; Cataract; Patient-reported outcomes measures
Citar a publicação
Queir?s L,Redondo P,França M,Silva SE,Borges P,de Melo AB,Pereira N,da PF,Carvalho N,Borges M,Sequeira I,Gonçalves FNR,Lemos J. Implementing ICHOM standard set for cataract surgery at IPO-Porto (Portugal): clinical outcomes, quality of life and costs. BMC Ophthalmol. 2021. 21. (1):119. IF:2,086. (3).
Portal de investigação
