- Início
- Publicações
- Real-life data on heart failure before and after implantation of resynchronization and/or defibrillation devices - the Sincrone study [Implanta??o de dispositivos de ressincroniza??o e/ou desfibrilha??o em doentes com insufici?ncia card?aca: dados da vida real ? o Estudo S?ncrone]
Real-life data on heart failure before and after implantation of resynchronization and/or defibrillation devices - the Sincrone study [Implanta??o de dispositivos de ressincroniza??o e/ou desfibrilha??o em doentes com insufici?ncia card?aca: dados da vida real ? o Estudo S?ncrone]
Autores da FMUP
Participantes de fora da FMUP
- Bonhorst, D
- Guerreiro, S
- Fonseca, C
- Cardim, N
- Adrag?o, P
Abstract
Introduction: The aim of this study was to document clinical practice in Portugal regarding the use of electronic cardiac devices in patients with heart failure (HF) and reduced left ventricular ejection fraction (LVEF). Methods: The S?ncrone study was an observational prospective multicenter registry conducted in 16 centers in Portugal between 2006 and 2014. It included adult patients with a diagnosis of HF, LVEF <35% and indication for implantable cardioverter?defibrillator (ICD) and/or cardiac resynchronization therapy (CRT) devices, according to the recommendations of the European Society of Cardiology at the beginning of the study. Patients were followed for one year according to the practice of each center. Results: A total of 486 patients were included in the registry, half of whom received an ICD and the other half a CRT pacemaker (CRT?P) or CRT defibrillator (CRT?D). Mean age was 65?12 years and the most frequent causes of HF were ischemic (47%) and idiopathic dilated cardiomyopathy (28%). Overall mortality at one year was 3.6% and the hospitalization rate was 11%, significantly higher in patients with CRT?P/CRT?D than with ICD (17% vs. 5.6%, p<0.001). Patients who received CRT?P/CRT?D experienced significant reductions in QRS duration (160?21 vs. 141?24 ms, p<0.001) as well as improvement in New York Heart Association functional class. Conclusion: The S?ncrone study shows that the use of implantable devices in HF with reduced LVEF in Portugal is in accordance with international recommendations and that patients presented functional improvement and reduced one?year mortality. ? 2019
Dados da publicação
- ISSN/ISSNe:
- 0870-2551, 2174-2030
- Tipo:
- Article
- Páginas:
- -
- PubMed:
- 30685295
Revista Portuguesa de Cardiologia Sociedade Portuguesa De Cardiologia
Citações Recebidas na Web of Science: 7
Citações Recebidas na Scopus: 7
Documentos
- Não há documentos
Filiações
Filiações não disponíveis
Citar a publicação
Bonhorst D,Guerreiro S,Fonseca C,Cardim N,Macedo F,Adrag?o P. Real-life data on heart failure before and after implantation of resynchronization and/or defibrillation devices - the Sincrone study [Implanta??o de dispositivos de ressincroniza??o e/ou desfibrilha??o em doentes com insufici?ncia card?aca: dados da vida real ? o Estudo S?ncrone]. Rev Port Cardiol. 2019. IF:0,960. (4).