Pulmonary function electronic monitoring devices - A randomized agreement study

Data de publicação:

Autores da FMUP

Participantes de fora da FMUP

  • Magalhaes, M
  • Castel Branco, MG
  • Vaz, M

Abstract

Study objectives: To compare in a clinical setting the within-session reproducibility, of two pulmonary function electronic monitoring devices (PiKo-1; Ferraris Respiratory Europe; Hereford, UK; and Spirotel; MIR; Rome, Italy) with one mechanical device (Mini-Wright Peak-Flow Meter; Clement-Clarke International; Harlow, Essex, UK), and to evaluate the accuracy of these devices using as reference an office pneumotachograph. Design, setting, and participants: After detailed instructions, adults without airways diseases and patients with stable asthma attending an outpatient clinic performed four sets of expiratory maneuvers, one set for each device, in a strictly, random order. Each set comprised three maneuvers with 2 to 3 min of rest between them. Measurements: Reproducibility of FEV1 and peak expiratory, flow (PEF) was assessed by a coefficient of variation (CV) and intraclass correlation coefficient (ICC), and accuracy was assessed by ICC and limits of agreement. Results: Of the 38 participants evaluated, 71% were women and 61% had asthma. Ages ranged from 18 to 58 years, and FEV1 ranged from 1.2 to 4.8 L. In all monitoring devices, CV was < 6% and ICC was > 0.94 for the reproducibility of both FEV, and PEF measurements. The accuracy of the PiKo-1 device was better for FEV, (ICC = 0.98) than for PEF (ICC = 0.90). The Spirotel device had similar results for FEV, and PEF (ICC = 0.95). The Mini-Wright device had the lowest accuracy (ICC = 0.87), particularly for PEF values < 500 L/min. Conclusions: These low-cost and easy-to-use electronic monitoring devices showed a very good reproducibility and were in agreement with the pneumotachograph. Therefore, the PiKo-I and Spirotel devices seem adequate for both screening and monitoring. However, prospective studies are still needed to assess their long-term reproducibility and usability and, particularly, the effects on the improvement of respiratory, care.

Dados da publicação

ISSN/ISSNe:
0012-3692, 1931-3543

Chest  American College of Chest Physicians

Tipo:
Article
Páginas:
1258-1265
PubMed:
16162716
Link para outro recurso:
www.scopus.com

Citações Recebidas na Web of Science: 45

Citações Recebidas na Scopus: 58

Documentos

  • Não há documentos

Métricas

Filiações

Filiações não disponíveis

Keywords

  • adult; article; asthma; biomedical technology assessment; clinical trial; comparative study; controlled clinical trial; controlled study; correlation coefficient; device; diagnostic accuracy; female; forced expiratory volume; human; lung function; lung function test; major clinical study; male; monitoring; outpatient; pneumotachygraphy; priority journal; quality of life; randomized controlled trial; reproducibility; screening

Citar a publicação

Partilhar a publicação