A comparison study of the reporting systems for salivary gland fine needle aspirations: Are they really different?

Data de publicação:

Autores da FMUP

Participantes de fora da FMUP

  • Montezuma, D
  • Canberk, S
  • Aydin, O
  • Dermirhas, MP
  • Vieira, AF
  • Goksel, S
  • Ince, U

Unidades de investigação

Abstract

Background Methods Recently a new system for reporting salivary gland fine-needle aspiration (FNA) cytology was proposed, the Milan System for Reporting Salivary Gland Cytopathology (MSRSGC). Herein, we evaluated diagnostic accuracy of salivary gland FNA, comparing the system previously used in our hospital with the Milan system. Salivary gland specimens obtained between 2011 and 2017 were reclassified according to MSRSGC. Risk of malignancy for each diagnostic category was determined. Diagnostic yield of both classifications was evaluated. Results Conclusions The cases (n = 388) were classified according to the old system: nondiagnostic (n = 28), benign (n = 246), atypical (n = 36), neoplastic (n = 57), suspicious for malignancy (n = 7) and malignant (n = 14). The lesions were distributed according to the MSRSGC: nondiagnostic (n = 28), non-neoplastic (n = 89), atypia of undetermined significance (n = 39), benign neoplasm (n = 156), neoplasm of uncertain malignant potential (n = 55), suspicious for malignancy (n = 7) and malignant (n = 14). When considering only benign and malignant cases, both classifications showed the same sensitivity (62.5%), specificity (100%) and similar accuracy (95.8%). Comparison between the two systems showed no significant difference. Salivary gland FNA has high diagnostic accuracy and assists clinical management independently of the reporting system used, however, in some cases, the use of Milan system could be beneficial, since it allows an enhanced category stratification.

Dados da publicação

ISSN/ISSNe:
8755-1039, 8755-1039

Diagnostic Cytopathology  Wiley-Liss Inc.

Tipo:
Article
Páginas:
859-863
PubMed:
30369104
Link para outro recurso:
www.scopus.com

Citações Recebidas na Web of Science: 18

Citações Recebidas na Scopus: 21

Documentos

  • Não há documentos

Métricas

Filiações

Filiações não disponíveis

Keywords

  • Adolescent; Adult; Aged; Biopsy, Fine-Needle; Child; Demography; Female; Humans; Male; Middle Aged; Predictive Value of Tests; Reference Standards; Research Report; Risk Factors; ROC Curve; Salivary Gland Neoplasms; Salivary Glands; Sensitivity and Specificity; Young Adult; adult; Article; benign neoplasm; cancer risk; cytodiagnosis; cytopathology; diagnostic accuracy; diagnostic test accuracy study; disease classification; female; fine needle aspiration biopsy; human; human tissue; intermethod comparison; major clinical study; male; malignant neoplasm; malignant transformation; Milan system; neoplasm; neoplasms of uncertain behavior; priority journal; receiver operating characteristic; salivary gland; sensitivity and specificity; adolescent; aged; child; comparative study; demography; fine needle aspiration biopsy; middle aged; pathology; predictive value; research; risk factor; salivary gland; salivary gland tumor; standard; young adult

Citar a publicação

Partilhar a publicação