Simultaneous temperature and strain measurements performed by a step-changed arc-induced long-period fiber grating.

Data de publicação:

Autores da FMUP

Participantes de fora da FMUP

  • Falate R
  • Ivanov O
  • Santos JL

Abstract

A compact sensor based on step-changed arc-induced long-period fiber gratings was implemented to discriminate between temperature and strain. The proposed sensor consists of a single long-period grating with two sections written consecutively in the SMF-28 fiber using the electric arc discharge technique. The two sections have the same period but different fabrication parameters. The operation of the sensor relies on the existence of a difference between the values of temperature and strain sensitivity of two neighboring resonances observed in the spectrum of the step-changed grating. The temperature and strain resolutions obtained for the sensor are 0.2 degrees C and 35 micro epsilon, respectively.

Dados da publicação

ISSN/ISSNe:
2155-3165, 1559-128X

Applied Optics  The Optical Society

Tipo:
Article
Páginas:
1392-1396
PubMed:
17334427

Citações Recebidas na Web of Science: 28

Documentos

  • Não há documentos

Métricas

Filiações mostrar / ocultar

Citar a publicação