A compact sensor based on step-changed arc-induced long-period fiber gratings was implemented to discriminate between temperature and strain. The proposed sensor consists of a single long-period grating with two sections written consecutively in the SMF-28 fiber using the electric arc discharge technique. The two sections have the same period but different fabrication parameters. The operation of the sensor relies on the existence of a difference between the values of temperature and strain sensitivity of two neighboring resonances observed in the spectrum of the step-changed grating. The temperature and strain resolutions obtained for the sensor are 0.2 degrees C and 35 micro epsilon, respectively.
Dados da publicação
- ISSN/ISSNe:
- 2155-3165, 1559-128X
- Tipo:
- Article
- Páginas:
- 1392-1396
- DOI:
- 10.1364/ao.46.001392
- PubMed:
- 17334427
Applied Optics The Optical Society
Citações Recebidas na Web of Science: 28
Documentos
- Não há documentos
Filiações
Citar a publicação
Rego G,Falate R,Ivanov O,Santos JL. Simultaneous temperature and strain measurements performed by a step-changed arc-induced long-period fiber grating. Appl. Opt. 2007. 46. (9):p. 1392-1396.