Treatment of severe dialysis reactions with the AN69-ST membrane: Biocompatibility does matter

Data de publicação: Data Ahead of Print:

Autores da FMUP

  • Manuel Jesus Falcão Pestana Vasconcelos

    Autor

Participantes de fora da FMUP

  • Coentr?o, L.
  • Martins, P
  • Leblanc, A
  • Botelho, C
  • Carvalho, BA

Abstract

Dialysis reactions with biocompatible membranes are rare, and complement activation has been suggested to be a culprit. We report here a case of an incident haemodialysis patient with asthma disease who experienced severe adverse reactions late into dialysis session, with different synthetic membranes (FX 80, Fresenius; Polyflux 17L, Gambro; FX 10, Fresenius; BLS 512, Bellco-Sorin). After replacing the dialyser by the surface-treated AN69 membrane (Nephral ST 500, Hospal), the dialysis sessions became uneventful. The case reinforces the need for biocompatible dialysers with high permeability and adsorptive capacity in susceptible patients experiencing severe dialysis reactions with synthetic membranes.

Dados da publicação

ISSN/ISSNe:
1753-0792, 2048-8513

CLINICAL KIDNEY JOURNAL  Oxford University Press

Tipo:
Article
Páginas:
298-299
PubMed:
28657048
Link para outro recurso:
www.scopus.com

Citações Recebidas na Web of Science: 4

Citações Recebidas na Scopus: 5

Documentos

  • Não há documentos

Métricas

Filiações

Filiações não disponíveis

Keywords

  • adrenalin; clemastine; hydrocortisone; aged; article; biocompatibility; bronchospasm; burning sensation; case report; dialysis membrane; dialysis reaction; disease severity; dyspnea; epiphora; female; hemodialysis; human; hypersensitivity reaction; hypoxemia; kidney failure; priority journal; respiratory distress