Hemodynamic and clinical performance of Solo stentless bioprosthetic aortic valves
Data de publicação:
Autores da FMUP
Participantes de fora da FMUP
- Andrade, M
- Saraiva, F
- Amorim, M.
- Marinho, B.
- Cerqueira, R.
- Louren?o, A.
- Pinho, P
- Almeida, J.
Unidades de investigação
Abstract
Objective: To report the hemodynamic profile and short- and medium-term outcomes of Free- replacement; dom Solo and Solo Smart stentless aortic valves implanted at our center. Methods: Between 2009 and 2015, all patients undergoing aortic valve replacement using Solo stentless valves at our center were enrolled. Clinical and echocardiographic follow-up was Cardiac surgery carried out six months postoperatively. Survival and major events, including structural valve deterioration and non-structural valve dysfunction, endocarditis, reoperation and stroke, were assessed through medical records or telephone interview with the referring cardiologist up to November 2015 (mean and maximum follow-up 39 +/- 22 and 78 months, respectively). Results: Patients (n=345) mean age was 72 +/- 8 years, 52% were female and median euroSCORE II was 2.7 (1.5-4.7). There was no intraoperative mortality and in-hospital mortality was 2.6%. Postoperatively, mean transvalvular gradient was 11.9 +/- 4.5 mmHg and effective orifice area was 1.9 +/- 0.5 cm(2). Patient-prosthesis mismatch occurred in 14% but was severe in only one patient. Cumulative survival at six years was 72%. Six patients were reoperated: three due to endocarditis, two for structural prosthesis deterioration and one because of periprosthetic fistula. Five patients suffered stroke, three had medically-treated endocarditis and one had structural valve deterioration but was not considered suitable for reoperation. None of the remainder had structural valve deterioration or non-structural valve dysfunction. Conclusions: Solo stentless aortic valves are safe to implant, with promising clinical outcomes in short- and medium-term assessment. Moreover, they show an excellent hemodynamic performance: low transvalvular gradients, large effective orifice areas and low incidence of patient-prosthesis mismatch.
Dados da publicação
- ISSN/ISSNe:
- 0870-2551, 2174-2030
- Tipo:
- Article
- Páginas:
- 811-818
- PubMed:
- 30274938
- Link para outro recurso:
- www.scopus.com
Revista Portuguesa de Cardiologia Sociedade Portuguesa De Cardiologia
Citações Recebidas na Web of Science: 4
Citações Recebidas na Scopus: 5
Documentos
- Não há documentos
Filiações
Filiações não disponíveis
Keywords
- Aortic valve replacement; Stentless aortic bioprosthesis; Cardiac surgery