Left Ventricular Diastolic Dysfunction and E/E ' Ratio as the Strongest Echocardiographic Predictors of Reduced Exercise Capacity After Acute Myocardial Infarction
Data de publicação:
Data Ahead of Print:
Autores da FMUP
Participantes de fora da FMUP
- Fontes Carvalho, R.
- Sampaio, F.
- Teixeira, M
- Rocha Goncalves, F
- Gama, V
- Azevedo, A.
Abstract
BackgroundThe mechanisms that determine reduced exercise capacity after acute myocardial infarction (AMI) are not fully understood, especially the relative role of left ventricular diastolic and systolic function. HypothesisTo evaluate the role of different diastolic and systolic function echocardiographic parameters as predictors of reduced functional capacity in patients after AMI. MethodsOne month after AMI, 225 patients (84% male; mean age, 55.110.9years) were enrolled and underwent detailed echocardiography and cardiopulmonary exercise test on the same day. Systolic and diastolic function was evaluated by echocardiography according to the latest consensus recommendations, including tissue Doppler evaluation. Exercise capacity was evaluated with peak oxygen consumption (VO2). ResultsPeak VO2 was significantly correlated with early diastolic tissue Doppler velocity (E) septal (r=0.42, P<0.001), E lateral (r=0.35, P<0.001), septal E/E ratio (r=-0.35, P=0.001), and lateral E/E (r=-0.27, P<0.001). These diastolic function parameters predicted impaired exercise capacity (VO2 <19 mL/kg/min), with an area under the receiver operating characteristic curve of 0.77 (95% confidence interval [CI]: 0.68-0.86, P<0.001) for septal E/E. On multivariate analysis, for each unit increase in septal E/E ratio there was a -0.35 (95% CI: -0.54 to -0.15) mL/kg/min decrease in peak VO2 independently of age, sex, body mass index, hypertension, and diabetes. There was a mild correlation between peak VO2 and systolic function parameters (r=0.17, P=0.01 with ejection fraction; and r=0.23, P=0.02 with lateral systolic tissue Doppler velocity) that persisted after multivariate adjustment. Conclusions<p id="clc22378-para-0004">After AMI, resting diastolic function parameters were the strongest correlates of exercise tolerance. Septal E/E ratio was the best echocardiographic predictor of reduced functional capacity.
© 2015 Wiley Periodicals, Inc.
Dados da publicação
- ISSN/ISSNe:
- 1932-8737, 0160-9289
- Tipo:
- Article
- Páginas:
- 222-229
- DOI:
- 10.1002/clc.22378
- PubMed:
- 25707582
- Link para outro recurso:
- www.scopus.com
Clinical Cardiology Wiley-Blackwell
Citações Recebidas na Web of Science: 26
Citações Recebidas na Scopus: 32
Documentos
- Não há documentos
Filiações
Filiações não disponíveis
Keywords
- Aged; Echocardiography; Exercise Test; Exercise Tolerance; Female; Humans; Male; Middle Aged; Myocardial Infarction; Ultrasonography, Doppler; Ventricular Dysfunction, Left; acute heart infarction; adult; area under the curve; Article; body mass; cardiopulmonary exercise test; cardiovascular parameters; consensus; diabetes mellitus; e e ratio; echocardiography; exercise; female; functional status; heart ejection fraction; heart left ventricle function; human; hypertension; left ventricular diastolic dysfunction; major clinical study; male; oxygen consumption; receiver operating characteristic; tissue Doppler imaging; velocity; aged; Doppler ultrasonography; echography; exercise test; exercise tolerance; heart infarction; middle aged; pathophysiology
Citar a publicação
Fontes R,Sampaio F,Teixeira M,Rocha F,Gama V,Azevedo A,Leite A. Left Ventricular Diastolic Dysfunction and E/E ' Ratio as the Strongest Echocardiographic Predictors of Reduced Exercise Capacity After Acute Myocardial Infarction. Clin. Cardiol. 2015. 38. (4):p. 222-229. IF:2,431. (2).