Additive Value of Magnetic Resonance Coronary Angiography in a Comprehensive Cardiac Magnetic Resonance Stress-Rest Protocol for Detection of Functionally Significant Coronary Artery Disease A Pilot Study
Data de publicação:
Data Ahead of Print:
Autores da FMUP
Participantes de fora da FMUP
- Bettencourt Sousa, N.
- Ferreira, N
- Chiribiri, A
- Schuster, A
- Sampaio, F.
- Santos, L
- Melica, B
- Rodrigues, A
- Braga, P
- Teixeira, M
- Silva Cardoso, J.
- Portugal, P
- Gama, V
- Nagel, E
Abstract
Background Cardiovascular magnetic resonance (CMR) myocardial perfusion imaging (MPI) is a state-of-the-art noninvasive modality for detection of myocardial ischemia and coronary artery disease. Magnetic resonance coronary angiography (MRCA) allows visualization of the coronary tree, but its incremental value as part of a CMR protocol including MPI and late gadolinium enhancement (LGE) is not well established. We aimed to evaluate the additive diagnostic value of a 3-dimensional whole-heart MRCA integration into a 1.5T CMR-MPI/LGE protocol for the detection of functionally significant coronary artery disease. Methods and Results Forty-three symptomatic patients (618.3 years; 65% men) with suspected coronary artery disease and intermediate/high-pretest probability underwent CMR (including CMR-MPI, MRCA, and LGE) and x-ray invasive coronary angiography (XA) with fractional flow reserve evaluation. Diagnostic performances of MRCA, CMR-MPI/LGE, and MRCA+CMR-MPI/LGE integration were determined having XA+fractional flow reserve as standard for coronary artery disease (90% stenosis/occlusion or fractional flow reserve0.80 in vessels>2 mm). MRCA inclusion into the CMR protocol was associated with a mean increase of 7.9 +/- 4.69 (0-17.7) minutes in total examination duration (14%). On patient-based analysis, MRCA had 96% sensitivity, 68% specificity, positive predictive value of 79%, and negative predictive value of 93%. CMR-MPI/LGE had 79% sensitivity, 95% specificity, positive predictive value of 95%, and negative predictive value of 78%. Integration of MRCA with CMR-MPI/LGE further improved CMR performance to 96% sensitivity, 89% specificity, positive predictive value of 92%, and negative predictive value of 94%, with a global accuracy of 93%. Conclusions In this intermediate/high-pretest population, integration of noncontrast-enhanced whole-heart MRCA nonsignificantly improved per-patient diagnostic accuracy of a comprehensive 1.5-T stress-rest CMR-MPI/LGE protocol at a cost of longer scanning times.
Dados da publicação
- ISSN/ISSNe:
- 1942-0080, 1941-9651
- Tipo:
- Article
- Páginas:
- 730-738
- PubMed:
- 23833284
- Link para outro recurso:
- www.scopus.com
CIRCULATION-CARDIOVASCULAR IMAGING Lippincott Williams and Wilkins Ltd.
Citações Recebidas na Web of Science: 20
Citações Recebidas na Scopus: 20
Documentos
- Não há documentos
Filiações
Filiações não disponíveis
Keywords
- coronary angiography; fractional flow reserve; myocardial; magnetic resonance imaging; perfusion imaging
Campos de Estudo
Citar a publicação
Bettencourt N,Ferreira N,Chiribiri A,Schuster A,Sampaio F,Santos L,Melica B,Rodrigues A,Braga P,Teixeira M,Leite A,Silva J,Portugal P,Gama V,Nagel E. Additive Value of Magnetic Resonance Coronary Angiography in a Comprehensive Cardiac Magnetic Resonance Stress-Rest Protocol for Detection of Functionally Significant Coronary Artery Disease A Pilot Study. Circ Cardiovasc Imaging. 2013. 6. (5):p. 730-738. IF:6,752. (1).
Portal de investigação
