Cardiac magnetic resonance myocardial perfusion imaging for detection of functionally significant obstructive coronary artery disease: A prospective study

Data de publicação: Data Ahead of Print:

Autores da FMUP

  • Joaquim Adelino Correia Ferreira Leite Moreira

    Autor

Participantes de fora da FMUP

  • Bettencourt Sousa, N.
  • Chiribiri, A
  • Schuster, A
  • Ferreira, N
  • Sampaio, F.
  • Duarte, R
  • Santos, L
  • Melica, B
  • Rodrigues, A
  • Braga, P
  • Teixeira, M
  • Simoes, L
  • Silva Cardoso, J.
  • Nagel, E
  • Portugal, P
  • Gama, V

Abstract

Background: Cardiac magnetic resonance myocardial perfusion imaging (CMR-MPI) is considered a state of the art non-invasive modality for the detection of reversible ischemia. Recent studies have shown its utility in the diagnosis of coronary artery disease (CAD) and superiority over other established techniques. However, only a few studies compared CMR-MPI against the invasive standard including fractional flow reserve (FFR) and clinical validation in non-specialized centers is scarce. The aim of this study was to validate CMR-MPI in a real-world clinical environment and to test its diagnostic accuracy in symptomatic patients with suspected CAD versus FFR as the reference standard of functionally significant disease. Methods and results: 103 symptomatic consecutive patients (62 +/- 8.0 years, 66% males) with suspected CAD and intermediate or high probability of disease underwent sequential CMR and invasive coronary angiography (XA). The CMR protocol included stress-rest adenosine perfusion, SSFP cine imaging and late-enhancement imaging. Functionally significant CAD was defined as occlusive/sub-occlusive stenoses on XA or non-occlusive stenoses with a FFR measurement of <0.80 in vessels >2 mm. On a patient-based model, CMR-MPI had sensitivity, specificity, positive and negative predictive values of 89%, 88%, 85%, and 91%, respectively, with a global accuracy of 88%. On a vessel-based analysis, these values were 80%, 93%, 79% and 94%, respectively, with a global accuracy of 90%. Conclusions: CMR-MPI had a very high accuracy for detection of functionally significant CAD as assessed by FFR in patients with intermediate to high pretest probability.

Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

Dados da publicação

ISSN/ISSNe:
1874-1754, 0167-5273

International Journal of Cardiology  Elsevier Ireland Ltd

Tipo:
Article
Páginas:
765-773
PubMed:
23102601
Link para outro recurso:
www.scopus.com

Citações Recebidas na Web of Science: 30

Citações Recebidas na Scopus: 35

Documentos

  • Não há documentos

Métricas

Filiações

Filiações não disponíveis

Keywords

  • Adenosine; Coronary artery disease; Cardiac magnetic resonance; Fractional flow reserve; Perfusion; Stress testing

Citar a publicação

Partilhar a publicação