Inhaler devices in asthma and COPD - An assessment of inhaler technique and patient preferences

Data de publicação: Data Ahead of Print:

Autores da FMUP

  • Ana Margarida Barbosa Ribeiro Pereira

    Autor

  • João De Almeida Lopes Da Fonseca

    Autor

Participantes de fora da FMUP

  • Chorao, P

Abstract

Background: Incorrect use of inhaler devices remains an obstacle for respiratory diseases management. We aimed to evaluate the frequency of inhaler technique errors; to determine the devices perceived as the easiest and favourite to use; to study the association of device type, demographics and patient preferences with inhaler technique (IT). Methods: Cross-sectional assessment of 301 adults, with asthma (194) or chronic pulmonary obstructive disease, undergoing treatment with Aerolizer((R)), Autohaler((R)), Breezehaler((R)), Diskus((R)), Handihater((R)), MDI without spacer, Miat-haler((R)), Novolizer((R)), Respimat((R)) and/or Turbohaler((R)). Patients completed self-assessment questionnaires and face-to-face interview, with demonstration of inhaler technique. The rate of wrong steps (number of wrong steps divided by number of total steps; RWS) was the primary outcome. Adjusted odds ratio (aOR) (95% confidence intervals [Cl]) for presenting >=1 IT errors were computed. Results: From the 464 inhaler technique performances, the median RWS was 18%. Turbohaler((R)) (21%) and Diskus((R)) (19%) were chosen as easiest and Novolizer((R)) (18%), Diskus((R)) (18%), Turbohaler((R)) (17%) as favourite for daily use. Females (aOR 2.68 [95% CI 1.55-4.65]; vs. males], patients with >64 yr (aOR 2.73 [95% CI 1.15-6.48]; vs <45 yr) and patients using Aerolizer or Handihaler (aOR 3.24 [95% CI 1.13-9.32] and aOR 3.71 [95% CI 1.38-10.2], respectively) were more likely to perform IT errors; otherwise, no association was found, including with using the favourite device (aOR 1.43 [95% CI 0.84-2.42]). Conclusion: The frequency of inhaler technique errors was high and no device was clearly preferred over the others. Using the preferred inhaler device was not associated with less errors.

Copyright © 2014 Elsevier Ltd. All rights reserved.

Dados da publicação

ISSN/ISSNe:
0954-6111, 1532-3064

Respiratory Medicine  W.B. Saunders Ltd

Tipo:
Article
Páginas:
968-975
PubMed:
24873873
Link para outro recurso:
www.scopus.com

Citações Recebidas na Web of Science: 102

Citações Recebidas na Scopus: 109

Documentos

  • Não há documentos

Métricas

Filiações

Filiações não disponíveis

Keywords

  • Asthma; COPD; Inhaler device; Inhaler technique; Patient preference

Partilhar a publicação