Comparation of three methods for measuring the Edge Bevel Radius of rectangular orthodontic wires: An in-vitro study.

Data de publicação: Data Ahead of Print:

Autores da FMUP

  • Rui Manuel Lopes Nunes

    Autor

Participantes de fora da FMUP

  • Neves JG
  • Santamaria-Jr M
  • Yagüe Ballester R
  • Costa AR
  • Vedovello SAS
  • Vedovello Filho M

Unidades de investigação

Abstract

OBJECTIVE: To establish a simplified method for measuring the edge bevel radius of 0.019×0.025-in steel rectangular orthodontic wires, achievable in the clinical environment, and to compare it with the photographic method. MATERIALS AND METHODS: Aided by the AutoCAD™ 2016 software, the theoretical mathematical relationship was determined between the edge rounding radius and cross-sectional dimensions (height, width, diagonals), through rectangle drawings that represent cross-sections. Two hundred segments (n=20) were obtained from the posterior portions of 100 archwires from 10 brands (Dentaurum™; American-Orthodontics™; GAC™; 3M-Unitek™; Abzil™; Morelli™; Orthometric™; Aditek™; A-Company™; Orthomundi™). The cross-sectional measures of each segment were obtained with a micrometer and a caliper, and the edge bevel radii of these segments were calculated with the use of a mathematical formula. For the "gold standard", the segments were included longitudinally in a phenolic resin cylinder, cross-sectioned, polished, and photographed in scanning electron microscope (SEM). The images were amplified 770× and the radii were measured with an acetate template. The micrometer and caliper measuring methods were subjected to Bland-Altman analysis and compared with the gold standard (SEM), considering ±10µm as the maximum acceptable difference between methods. RESULTS: In the micrometre measurement, 95% of the differences from the standard were within the limits of agreement (-7.21 and 5.56µm). For the caliper method, 95% of the differences were between -5.46 and 19.83µm, which exceeded the fixed limit ±10µm. CONCLUSION: The calculation method with micrometre measurements is equivalent to the photographic method, but there is no such equivalence for the caliper measurements.

Copyright © 2020 CEO. Published by Elsevier Masson SAS. All rights reserved.

Dados da publicação

ISSN/ISSNe:
1761-7227, 1879-680X

International Orthodontics  Elsevier Masson s.r.l.

Tipo:
Article
Páginas:
509-518

Documentos

  • Não há documentos

Métricas

Filiações mostrar / ocultar

Keywords

  • Orthodontics; Rectangular archwires; Torque

Proyectos asociados

Ameaça aos princípios bioéticos na pratica médica no Brasil: Duas Décadas dos Processos ético-profissionais (1988-2008)

Investigador Principal: Rui Manuel Lopes Nunes

Estudo Clínico Académico . 2019

Citar a publicação

Partilhar a publicação