Comparation of three methods for measuring the Edge Bevel Radius of rectangular orthodontic wires: An in-vitro study.
Autores da FMUP
Participantes de fora da FMUP
- Neves JG
- Santamaria-Jr M
- Yagüe Ballester R
- Costa AR
- Vedovello SAS
- Vedovello Filho M
Unidades de investigação
Abstract
OBJECTIVE: To establish a simplified method for measuring the edge bevel radius of 0.019×0.025-in steel rectangular orthodontic wires, achievable in the clinical environment, and to compare it with the photographic method. MATERIALS AND METHODS: Aided by the AutoCAD™ 2016 software, the theoretical mathematical relationship was determined between the edge rounding radius and cross-sectional dimensions (height, width, diagonals), through rectangle drawings that represent cross-sections. Two hundred segments (n=20) were obtained from the posterior portions of 100 archwires from 10 brands (Dentaurum™; American-Orthodontics™; GAC™; 3M-Unitek™; Abzil™; Morelli™; Orthometric™; Aditek™; A-Company™; Orthomundi™). The cross-sectional measures of each segment were obtained with a micrometer and a caliper, and the edge bevel radii of these segments were calculated with the use of a mathematical formula. For the "gold standard", the segments were included longitudinally in a phenolic resin cylinder, cross-sectioned, polished, and photographed in scanning electron microscope (SEM). The images were amplified 770× and the radii were measured with an acetate template. The micrometer and caliper measuring methods were subjected to Bland-Altman analysis and compared with the gold standard (SEM), considering ±10µm as the maximum acceptable difference between methods. RESULTS: In the micrometre measurement, 95% of the differences from the standard were within the limits of agreement (-7.21 and 5.56µm). For the caliper method, 95% of the differences were between -5.46 and 19.83µm, which exceeded the fixed limit ±10µm. CONCLUSION: The calculation method with micrometre measurements is equivalent to the photographic method, but there is no such equivalence for the caliper measurements.
Copyright © 2020 CEO. Published by Elsevier Masson SAS. All rights reserved.
Dados da publicação
- ISSN/ISSNe:
- 1761-7227, 1879-680X
- Tipo:
- Article
- Páginas:
- 509-518
International Orthodontics Elsevier Masson s.r.l.
Documentos
- Não há documentos
Filiações
Keywords
- Orthodontics; Rectangular archwires; Torque
Proyectos asociados
Ameaça aos princípios bioéticos na pratica médica no Brasil: Duas Décadas dos Processos ético-profissionais (1988-2008)
Investigador Principal: Rui Manuel Lopes Nunes
Estudo Clínico Académico . 2019
Citar a publicação
Nunes R,Neves JG,Santamaria M,Yagüe R,Costa AR,Vedovello S,Vedovello M. Comparation of three methods for measuring the Edge Bevel Radius of rectangular orthodontic wires: An in-vitro study. Int Orthod. 2020. 18. (3):p. 509-518.