Accuracy of twenty-four-hour ambulatory blood pressure monitoring (night-day values) for the diagnosis of secondary hypertension

Data de publicação:

Autores da FMUP

  • Jorge Manuel Da Silva Junqueira Polónia

    Autor

  • Ana Cristina Correia Dos Santos

    Autor

  • José Henrique Dias Pinto De Barros

    Autor

Participantes de fora da FMUP

  • Gama, GM

Abstract

Objectives: To determine the accuracy of 24-h ambulatory blood pressure monitoring, using the relationship between night-time and daytime values, in diagnosing secondary hypertension. Patients and methods: A prospective study was performed in a referred population of 402 hypertensive patients (clinic systolic/diastolic blood pressure >140/90 mmHg). The ambulatory monitoring data included 24-h mean, awake (daytime) and sleeping (night-time) values. Secondary hypertension was diagnosed by standard procedures. To describe the accuracy of ambulatory blood pressure monitoring, receiver-operator characteristic curves were constructed, using sensitivity and specificity values for deciles of the distribution of overnight blood pressure falls (absolute and percentage). Measurements included the fall in nocturnal blood pressure, sensitivity (the percentage of those with secondary hypertension who were classified as non-dippers), specificity (the percentage of non-secondary hypertensives who were classified as dippers) and predictive values of ambulatory blood pressure monitoring. Results: On average, overnight systolic/diastolic blood pressure fell in primary hypertensives (n = 290) by 20/18mmHg (13%/19%), in white-coat hypertensives (n = 65, day time ambulatory blood pressure <135/87mmHg) by 17/15mmHg (13%/19%) and in patients with secondary hypertension (n = 47, renal/renovascular and endocrine forms) by 13/11 mmHg (9%/12%). From receiver-operator characteristic curves, the nocturnal blood pressure fall of 15 mmHg showed the highest accuracy, with a sensitivity/specificity of 61%/69% (systolic) and 75%/62% (diastolic) whereas 10% (systolic) and 15% (diastolic) nocturnal falls had a sensitivity/specificity of 62%/74% (systolic) and 62%/70% (diastolic). The ambulatory blood pressure data had a high (>93%) negative predictive value for secondary hypertension. Conclusions: Secondary hypertension is associated with a blunted nocturnal fall in blood pressure. Ambulatory blood pressure monitoring data are not critically important for the diagnosis and screening of secondary hypertension but may be helpful in excluding it.

Dados da publicação

ISSN/ISSNe:
1473-5598, 0263-6352

Journal of Hypertension  Lippincott Williams and Wilkins Ltd.

Tipo:
Article
Páginas:
1738-1741
DOI:
PubMed:
8903643
Link para outro recurso:
www.scopus.com

Citações Recebidas na Web of Science: 10

Citações Recebidas na Scopus: 11

Documentos

  • Não há documentos

Métricas

Filiações

Filiações não disponíveis

Keywords

  • ambulatory blood pressure; receiver-operator characteristic curves; secondary hypertension