Retest variability and patient reliability indices of quantitative fundus autofluorescence in age-related macular degeneration: a MACUSTAR study report
Data de publicação:
Autores da FMUP
Participantes de fora da FMUP
- von der Emde L.
- Mallwitz M.
- Vaisband M.
- Hasenauer J.
- Saßmannshausen M.
- Terheyden J.H.
- Agostini H.
- Altay L.
- Atia R.
- Bandello F.
- Basile P.G.
- Batuca J.
- Behning C.
- Belmouhand M.
- Berger M.
- Binns A.
- Boon C.J.F.
- Böttger M.
- Bouchet C.
- Brazier J.E.
- Butt T.
- Carapezzi C.
- Carlton J.
- Carneiro A.
- Charil A.
- Coimbra R.
- Cozzi M.
- Crabb D.P.
- Cunha-Vaz J.
- Dahlke C.
- de Sisternes L.
- Dunbar H.
- Finger R.P.
- Fletcher E.
- Floyd H.
- Francisco C.
- Gutfleisch M.
- Hinz S.
- Hogg R.
- Holz F.G.
- Hoyng C.B.
- Kilani A.
- Krätzschmar J.
- Kühlewein L.
- Larsen M.
- Leal S.
- Lechanteur Y.T.E.
- Luhmann U.F.O.
- Lüning A.
- Marques I.
- Martinho C.
- Montesano G.
- Mulyukov Z.
- Paques M.
- Parodi B.
- Parravano M.
- Penas S.
- Peters T.
- Peto T.
- Pfau M.
- Poor S.
- Priglinger S.
- Rowen D.
- Rubin G.S.
- Sahel J.
- Sánchez C.
- Sander O.
- Schmid M.
- Schmitz-Valckenberg S.
- Siedlecki J.
- Skelly A.
- Souied E.
- Staurenghi G.
- Stöhr L.
- Taylor D.J.
- Thiele S.
- Tufail A.
- Varano M.
- Vieweg L.
- Wintergerst L.
- Wolf A.
- Zakaria N.
- Sloan K.R.
- Ach T.
Unidades de investigação
Abstract
This study aimed to determine the retest variability of quantitative fundus autofluorescence (QAF) in patients with and without age-related macular degeneration (AMD) and evaluate the predictive value of patient reliability indices on retest reliability. A total of 132 eyes from 68 patients were examined, including healthy individuals and those with various stages of AMD. Duplicate QAF imaging was conducted at baseline and 2 weeks later across six study sites. Intraclass correlation (ICC) analysis was used to evaluate the consistency of imaging, and mean opinion scores (MOS) of image quality were generated by two researchers. The contribution of MOS and other factors to retest variation was assessed using mixed-effect linear models. Additionally, a Random Forest Regressor was trained to evaluate the extent to which manual image grading of image quality could be replaced by automated assessment (inferred MOS). The results showed that ICC values were high for all QAF images, with slightly lower values in AMD-affected eyes. The average inter-day ICC was found to be 0.77 for QAF segments within the QAF8 ring and 0.74 for peripheral segments. Image quality was predicted with a mean absolute error of 0.27 on a 5-point scale, and of all evaluated reliability indices, MOS/inferred MOS proved most important. The findings suggest that QAF allows for reliable testing of autofluorescence levels at the posterior pole in patients with AMD in a multicenter, multioperator setting. Patient reliability indices could serve as eligibility criteria for clinical trials, helping identify patients with adequate retest reliability. © 2023, Springer Nature Limited.
Dados da publicação
- ISSN/ISSNe:
- 2045-2322, 2045-2322
- Tipo:
- Article
- Páginas:
- -
- PubMed:
- 37833348
- Link para outro recurso:
- www.scopus.com
Scientific Reports Nature Publishing Group
Citações Recebidas na Web of Science: 9
Citações Recebidas na Scopus: 9
Documentos
- Não há documentos
Filiações
Keywords
- Fluorescein Angiography; Fundus Oculi; Humans; Macular Degeneration; Reproducibility of Results; Retinal Pigment Epithelium; clinical trial; diagnostic imaging; eye fundus; fluorescence angiography; human; macular degeneration; multicenter study; procedures; reproducibility; retinal pigment epithelium
Citar a publicação
von der Emde L,Mallwitz M,Vaisband M,Hasenauer J,Saßmannshausen M,Terheyden JH,Agostini H,Altay L,Atia R,Bandello F,Basile PG,Batuca J,Behning C,Belmouhand M,Berger M,Binns A,Boon CJF,Böttger M,Bouchet C,Brazier JE,Butt T,Carapezzi C,Carlton J,Carneiro A,Charil A,Coimbra R,Cozzi M,Crabb DP,Cunha J,Dahlke C,de Sisternes L,Dunbar H,Finger RP,Fletcher E,Floyd H,Francisco C,Gutfleisch M,Hinz S,Hogg R,Holz FG,Hoyng CB,Kilani A,Krätzschmar J,Kühlewein L,Larsen M,Leal S,Lechanteur YTE,Luhmann UFO,Lüning A,Marques I,Martinho C,Montesano G,Mulyukov Z,Paques M,Parodi B,Parravano M,Penas S,Peters T,Peto T,Pfau M,Poor S,Priglinger S,Rowen D,Rubin GS,Sahel J,Sánchez C,Sander O,Schmid M,Schmitz S,Siedlecki J,Silva R,Skelly A,Souied E,Staurenghi G,Stöhr L,Taylor DJ,Thiele S,Tufail A,Varano M,Vieweg L,Wintergerst L,Wolf A,Zakaria N,Sloan KR,Ach T. Retest variability and patient reliability indices of quantitative fundus autofluorescence in age-related macular degeneration: a MACUSTAR study report. Sci. Rep. 2023. 13. (1):17417. IF:4,600. (2).