Alteraci?n del strain auricular izquierdo como predictor de fibrilaci?n auricular de nuevo comienzo tras recambio valvular a?rtico, independientemente del tama?o de la aur?cula izquierda
Autores da FMUP
Participantes de fora da FMUP
- Pessoa-Amorim, G
- Vouga, L
- Ribeiro, J
- Gama, V
Unidades de investigação
Abstract
Introduction and objectives: Left atrial dysfunction in aortic stenosis may precede atrial enlargement and predict the occurrence of atrial fibrillation (AF). To test this hypothesis, we assessed left atrial function and determined its impact on the incidence of AF after aortic valve replacement. Methods: A total of 149 severe aortic stenosis patients (74 +/- 8.6 years, 51% men) with no prior AF were assessed using speckle-tracking echocardiography. Left atrial function was evaluated using peak atrial longitudinal strain (PALS), peak atrial contraction strain (PACS), and phasic left atrial volumes. The occurrence of AF was monitored in 114 patients from surgery until hospital discharge. Results: In multiple linear regression, PALS and PACS were inversely correlated with left atrial dilation, left ventricular hypertrophy, and diastolic function. Atrial fibrillation occurred in 36 patients within a median time of 3 days [interquartile range, 1-4] after aortic valve replacement. In multiple Cox regression, PALS and PACS were independently associated with the incidence of AF (HR, 0.946; 95%Cl, 0.910-0.983; P = .005 and HR, 0.932; 95%CI, 0.883-0.984; P = .011, respectively), even after further adjustment for left atrial dimensions. Both reduced PALS and PACS were associated with the incidence of AF in patients with nondilated left atria (P value for the interaction of PAIS with left atrial dimensions = .013). Conclusions: In severe aortic stenosis, left atrial dysfunction predicted the incidence of postoperative AF independently of left atrial dilation, suggesting that speckle-tracking echocardiography before surgery may help in risk stratification, particularly in patients with nondilated left atria.
Dados da publicação
- ISSN/ISSNe:
- 1579-2242, 0300-8932
- Tipo:
- Article
- Páginas:
- 466-476
- PubMed:
- 29146482
- Link para outro recurso:
- www.scopus.com
Revista Espanola de Cardiologia Ediciones Doyma, S.L.
Citações Recebidas na Web of Science: 36
Citações Recebidas na Scopus: 41
Documentos
- Não há documentos
Filiações
Filiações não disponíveis
Keywords
- Aged; Aortic Valve; Aortic Valve Stenosis; Atrial Fibrillation; Atrial Function, Left; Echocardiography; Female; Heart Valve Prosthesis Implantation; Humans; Male; Postoperative Complications; Risk Assessment; Stress, Physiological; aged; aortic valve replacement; aortic valve stenosis; Article; cardiovascular parameters; cardiovascular risk; diastole; disease severity; female; heart atrium contraction; heart atrium function; heart disease; heart left atrial dysfunction; heart left atrium dilation; heart left atrium size; heart left atrium strain; heart left atrium volume; heart left ventricle hypertrophy; heart volume; hospital discharge; human; incidence; major clinical study; male; new-onset atrial fibrillation; patient monitoring; postoperative complication; risk assessment; speckle tracking echocardiography; aortic valve; aortic valve stenosis; atrial fibrillation; echocardiography; heart atrium function; heart valve replacement; pathophysiology; physiological stress; physiology;
Citar a publicação
Pessoa G,Mancio J,Vouga L,Ribeiro J,Gama V,Bettencourt N,Fontes R. Alteraci?n del strain auricular izquierdo como predictor de fibrilaci?n auricular de nuevo comienzo tras recambio valvular a?rtico, independientemente del tama?o de la aur?cula izquierda. Rev. Esp. Cardiol. 2018. 71. (6):p. 466-476. IF:5,126. (1).
Portal de investigação
