Development and evaluation of an algorithm for computer analysis of maternal heart rate during labor
Autores da FMUP
Participantes de fora da FMUP
- Pinto, Paula
- Amorim-Costa, Celia
- Silva, Maria
- Ayres-de-Campos, Diogo
Abstract
Background: Maternal heart rate (MHR) recordings are morphologically similar and sometimes coincident with fetal heart rate (FHR) recordings and may be useful for maternal-fetal monitoring if appropriately interpreted. However, similarly to FHR, visual interpretation of MHR features may be poorly reproducible. Methods: A computer algorithm for on-line MHR analysis was developed based on a previously existing version for FHR analysis. Inter-observer and computer-observer agreement and reliability were assessed in 40 one-hour recordings obtained from 20 women during the last 2 h of labor. Agreement and reliability were evaluated for the detection of basal MHR, long-term variability (LTV), accelerations and decelerations, using proportions of agreement (PA) and Kappa statistic (K), with 95% confidence intervals (95% Cl). Changes in MHR characteristics between the first and the second hour of the tracings were also evaluated. Results: There was a statistically significant inter-observer and computer-observer agreement and reliability in estimation of basal MHR, accelerations, decelerations and LTV, with PA values ranging from 0.72 (95% CI: 0.62-0.79) to 1.00 (95% CI: 0.99-1.00), and K values ranging from 0.44(95% CI: 0.28-0.60) to 0.89 (95% CI: 0.82-0.96). Moreover, basal MHR, number of accelerations and LTV were significantly higher in the last hour of labor, when compared to the initial hour. Discussion: The developed algorithm for on-line computer analysis of MHR recordings provided good to excellent computer-observer agreement and reliability. Moreover, it allowed an objective detection of MHR changes associated with labor progression, providing more information about the interpretation of maternal-fetal monitoring during labor. (C) 2014 Elsevier Ltd. All rights reserved.
Dados da publicação
- ISSN/ISSNe:
- 0010-4825, 1879-0534
- Tipo:
- Article
- Páginas:
- 30-35
- PubMed:
- 24727565
- Link para outro recurso:
- www.scopus.com
Computers in Biology and Medicine Elsevier Ltd.
Citações Recebidas na Web of Science: 15
Citações Recebidas na Scopus: 19
Documentos
- Não há documentos
Filiações
Keywords
- Fetal heart rate; Maternal heart rate; Cardiotocography; Computer analysis; Agreement; Reliability
Citar a publicação
Pinto P,Bernardes J,Costa C,Amorim C,Silva M,Ayres D. Development and evaluation of an algorithm for computer analysis of maternal heart rate during labor. Comput. Biol. Med. 2014. 49. (1):p. 30-35. IF:1,240. (3).
Portal de investigação