Ascending aorta in tetralogy of Fallot: Beyond echocardiographic dimensions

Data de publicação:

Autores da FMUP

  • José Carlos De Magalhães Silva Cardoso

    Autor

Participantes de fora da FMUP

  • Cruz, M.
  • Pinho, T
  • Sousa, C.
  • Dias, C.
  • Maciel, M.

Unidades de investigação

Abstract

BackgroundLate after tetralogy of Fallot (TOF) repair some patients exhibit aortic dilatation and stiffness. Noninvasive assessment of aortic stiffness could contribute to understand this aortopathy and may be important in risk stratification for major aortic event. MethodsWe included prospectively 82 adults after TOF repair and 41 age- and sex-matched normal controls. Aortic diameters were measured by two-dimensional transthoracic echocardiography and the aortic z-score was estimated. Aortic deformation was assessed by M-mode strain and global peak circumferential ascending aortic strain (CAAS), derived from two-dimensional speckle tracking echocardiography (2D-STE). Corrected CAAS was calculated as CAAS/pulse pressure. Ascending aorta (AAo) distensibility and stiffness index were calculated. ResultsTOF patients (age 29.78.4years; follow-up since TOF repair 23.0 +/- 6.8years) had smaller body surface area but a larger aorta compared to controls. TOF patients had lower AAo distensibility (2.2 [0.0-21.0] vs 5.6 [0.0-12.5] cm(2)dyne(-1)10(-6), P<.01), higher aortic stiffness index (9.5 [2.7-98.4] vs 7.1 [2.3-20.4], P=.02) and lower CAAS (6.0 +/- 3.9 vs 8.1 +/- 4.4%, P=.01) compared to controls. CAAS showed a better correlation with AAo z-score (r=-.25, P=.03) compared to M-mode strain. Systemic arterial compliance, arterial stiffness and corrected CAAS (=-0.23, P=.02) were independently associated with AAo diameter. ConclusionsTOF patients have a larger and stiffer AAo compared to controls. CAAS derived from 2D-STE allows a routine noninvasive method for assessing AAo stiffness, with advantages over M-mode strain, and may be used as predictor of major aortic or cardiovascular events.

Dados da publicação

ISSN/ISSNe:
0742-2822, 1540-8175

ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES  Wiley-Blackwell Publishing Ltd

Tipo:
Article
Páginas:
1362-1369
PubMed:
29900594
Link para outro recurso:
www.scopus.com

Citações Recebidas na Web of Science: 13

Citações Recebidas na Scopus: 13

Documentos

  • Não há documentos

Métricas

Filiações

Filiações não disponíveis

Keywords

  • tetralogy of Fallot; thoracic aorta; tissue and strain Doppler echocardiography

Citar a publicação

Partilhar a publicação