Monitoring Crohn's disease activity: endoscopy, fecal markers and computed tomography enterography
Data de publicação:
Autores da FMUP
Participantes de fora da FMUP
- Andrade, P
- Afonso, J
- Cunha, R
Unidades de investigação
Abstract
Background: The treatment goal of Crohns disease (CD) has moved towards achieving mucosal healing, resolution of transmural inflammation, and normalization of biomarkers. The purpose of this study was to evaluate how well computed tomography enterography (CTE) and fecal calprotectin (FC) correlated with endoscopic activity in newly diagnosed patients with CD and after 1 year of therapy. Methods: Consecutive patients with newly diagnosed CD were evaluated by endoscopy, CTE, and FC at diagnosis and 12 months after beginning immunosuppression. Endoscopic severity was assessed using the Simplified Endoscopic Score for Crohns Disease (SES-CD). Biomarkers, clinical indexes, and FC were recorded on the day of ileocolonoscopy at diagnosis and 1 year after diagnosis. We adapted a CTE score for disease activity based on radiological signs of inflammation (i.e. mural thickness, mural hyperenhancement, mesenteric fat proliferation, mesenteric fat densification, comb sign, presence of strictures, fistulas, abscesses, ascites, and lymphadenopathy). Correlations between endoscopy, CTE, and FC were assessed using Spearmans rank correlation. Results: A total of 29 patients (48% women; median age 30 (24.5-35.5) years) were included in this prospective cohort. CTE findings significantly correlated with endoscopic findings. Endoscopic remission (ER) at 1-year follow up significantly correlated with improvement in mural hyperenhancement (p = 0.004), mesenteric fat densification (p = 0.001), comb sign (p = 0.004), and strictures (p = 0.008) in CTE. None of the CTE findings improved in patients without ER. FC correlated with SES-CD (rs = 0.696, p < 0.001) and with CTE features of inflammation (rs = 0.596, p < 0.001). A cut-off of 100 mu g/g predicted ER with 92% sensitivity, 65% specificity, and 83% accuracy (area under curve 0.878, p < 0.001). Conclusions: CTE findings and FC levels correlated with endoscopic activity in CD both at diagnosis and at 1-year follow up. These two noninvasive markers of disease activity may be used as an alternative to endoscopy to monitor disease response to therapy.
Dados da publicação
- ISSN/ISSNe:
- 1756-283X, 1756-2848
- Tipo:
- Article
- Páginas:
- -
- PubMed:
- 29760785
- Link para outro recurso:
- www.scopus.com
Therapeutic Advances in Gastroenterology SAGE Publications Ltd
Citações Recebidas na Web of Science: 30
Citações Recebidas na Scopus: 30
Documentos
- Não há documentos
Filiações
Filiações não disponíveis
Keywords
- computed tomography enterography; Crohn's disease; disease monitoring; fecal calprotectin; ileocolonoscopy; mucosal healing
Citar a publicação
Lopes S,Andrade P,Afonso J,Cunha R,Rodrigues E,Ramos I,Macedo G,Magro F. Monitoring Crohn's disease activity: endoscopy, fecal markers and computed tomography enterography. Ther. Adv. Gastroenterol. 2018. 11. IF:3,961. (2).
Portal de investigação
