Potential Impact of Flow Cytometry Antimicrobial Susceptibility Testing on the Clinical Management of Gram-Negative Bacteremia Using the FASTinov (R) Kit

Data de publicação:

Autores da FMUP

  • Ana Sofia Quinta E Costa Neves Oliveira

    Autor

  • Ricardo Filipe Sousa Santos

    Autor

  • Acácio Agostinho Gonçalves Rodrigues

    Autor

  • José Artur Osório De Carvalho Paiva

    Autor

  • Cidália Irene Azevedo Pina Vaz

    Autor

Participantes de fora da FMUP

  • Silva, AP
  • Pinho, E
  • Mergulh?o Gomes, P.
  • Silva Dias, A
  • Marques, N
  • Martins Oliveira, I
  • Canton, R

Abstract

Laboratory assessment of antimicrobial susceptibility is a prerequisite for adequate management of infections. The aim of this research was to evaluate the performance of the novel FASTinov (R) kit for antimicrobial susceptibility testing (AST) of Gram negative bacilli directly on positive blood cultures. One hundred and two positive blood cultures from patients of a Portuguese University Hospital were included. AST were performed with routinemethod, Vitek2, with FASTinov (R) kit, and with the gold standardmicrodilution. Bacteria directly extracted from blood cultures were used to inoculate the FASTinov (R) kit. Time-to-result as well as the number of patients receiving initially inappropriate therapy (and those in whom de-escalation would have been done) and length of stay (LOS) was recorded. Seventy percent of patients were over 70 years old and 18.6% were admitted in intensive care units. Regarding the isolates, 88.2% were Enterobacteriaceae, 9.8% Pseudomonas spp. and 1% Acinetobacter spp. Extended spectrum beta-lactamases producing-Enterobacteriaceae were found in 7.8% of cases and 10.8% were multi-drug resistant. Fifty-one hours was the mean of time-to-result for routine test (Vitek2) vs. 2 h response regarding Fastinov r test. The overall agreement between FASTinov (R) and the reference microdilution method was 98%. According to the susceptibility phenotype, 16.7% of patients received initially inappropriate therapy and the mean hospital LOS of these patients was significantly higher. FASTinov r kit revealed an excellent correlation with the AST standard method and provided much earlier results than Vitek2.

Dados da publicação

ISSN/ISSNe:
1664-302X, 1664-302X

Frontiers in Microbiology  Frontiers Media S.A.

Tipo:
Article
Páginas:
-
PubMed:
29312169
Link para outro recurso:
www.scopus.com

Citações Recebidas na Web of Science: 29

Citações Recebidas na Scopus: 32

Documentos

  • Não há documentos

Métricas

Filiações

Filiações não disponíveis

Keywords

  • flow cytometry; antibacterial susceptibility; de-escalation; bacteremia; blood culture