Validity, reliability and minimal detectable change of the balance evaluation systems test (BESTest), mini-BESTest and brief-BESTest in patients with end-stage renal disease
Data de publicação:
Autores da FMUP
Participantes de fora da FMUP
- Flores, Ines
- Martins, Filipa
- Castro, Conceicao
- McPhee, Charlotte C.
- Shepherd, Ellen
- Demain, Sara
- Figueiredo, Daniela
- Marques, Alda
Unidades de investigação
Abstract
Purpose: This study determined the validity, test-retest reliability and minimal detectable change of the balance evaluation systems test (BESTest), mini-balance evaluation systems test (Mini-BESTest) and brief-balance evaluation systems test (Brief-BESTest) in patients with end-stage renal disease. Methods: A cross-sectional study with 74 patients with end-stage renal disease (male 66.2%; 63.9 +/- 15.1 years old) was conducted. Participants were asked to report the number of falls during the previous 12 months and to complete the activity-specific balance confidence (ABC) scale. The BESTest was administered, and the Mini-BESTest and Brief-BESTest scores were computed based on the BESTest performance. Validity was assessed by correlating balance tests with each other and with the ABC scale. Test-retest relative reliability and agreement were explored with the intraclass correlation coefficient (ICC) equation (2,1) and the Bland and Altman method. Minimal detectable changes at the 95% confidence level were established. Results: Balance test scores were significantly correlated with each other (spearman's correlation = 0.89-0.92) and with the ABC scale (spearman's correlation = 0.49-0.59). Balance tests presented high test-retest reliability (ICC = 0.84-0.94), with no evidence of bias. Minimal detectable change values were 10.8 (expressed as a percentage 13.5%), 5.3 (23.7%) and 5.6 (34%) points for the BESTest, Mini-BESTest and Brief-BESTest, respectively. Conclusions: All tests are valid and reliable to assess balance in patients with end-stage renal disease. Nevertheless, based on the minimal detectable changes found, BESTest and Mini-BESTest may be the most recommended tests for this specific population. .
Dados da publicação
- ISSN/ISSNe:
- 0963-8288, 1464-5165
- Tipo:
- Article
- Páginas:
- 3171-3176
- PubMed:
- 28886676
- Link para outro recurso:
- www.scopus.com
Disability and Rehabilitation Informa Healthcare
Citações Recebidas na Web of Science: 11
Citações Recebidas na Scopus: 12
Documentos
- Não há documentos
Filiações
Keywords
- Chronic kidney failure; dialysis; postural balance; risk assessment; reproducibility of results
Citar a publicação
Jacome C,Flores I,Martins F,Castro C,McPhee CC,Shepherd E,Demain S,Figueiredo D,Marques A. Validity, reliability and minimal detectable change of the balance evaluation systems test (BESTest), mini-BESTest and brief-BESTest in patients with end-stage renal disease. Disabil. Rehabil. 2018. 40. (26):p. 3171-3176. IF:2,054. (1).
Portal de investigação