Validity, reliability and minimal detectable change of the balance evaluation systems test (BESTest), mini-BESTest and brief-BESTest in patients with end-stage renal disease

Data de publicação:

Autores da FMUP

  • Cristina Isabel Oliveira Jácome

    Autor

Participantes de fora da FMUP

  • Flores, Ines
  • Martins, Filipa
  • Castro, Conceicao
  • McPhee, Charlotte C.
  • Shepherd, Ellen
  • Demain, Sara
  • Figueiredo, Daniela
  • Marques, Alda

Unidades de investigação

Abstract

Purpose: This study determined the validity, test-retest reliability and minimal detectable change of the balance evaluation systems test (BESTest), mini-balance evaluation systems test (Mini-BESTest) and brief-balance evaluation systems test (Brief-BESTest) in patients with end-stage renal disease. Methods: A cross-sectional study with 74 patients with end-stage renal disease (male 66.2%; 63.9 +/- 15.1 years old) was conducted. Participants were asked to report the number of falls during the previous 12 months and to complete the activity-specific balance confidence (ABC) scale. The BESTest was administered, and the Mini-BESTest and Brief-BESTest scores were computed based on the BESTest performance. Validity was assessed by correlating balance tests with each other and with the ABC scale. Test-retest relative reliability and agreement were explored with the intraclass correlation coefficient (ICC) equation (2,1) and the Bland and Altman method. Minimal detectable changes at the 95% confidence level were established. Results: Balance test scores were significantly correlated with each other (spearman's correlation = 0.89-0.92) and with the ABC scale (spearman's correlation = 0.49-0.59). Balance tests presented high test-retest reliability (ICC = 0.84-0.94), with no evidence of bias. Minimal detectable change values were 10.8 (expressed as a percentage 13.5%), 5.3 (23.7%) and 5.6 (34%) points for the BESTest, Mini-BESTest and Brief-BESTest, respectively. Conclusions: All tests are valid and reliable to assess balance in patients with end-stage renal disease. Nevertheless, based on the minimal detectable changes found, BESTest and Mini-BESTest may be the most recommended tests for this specific population. .

Dados da publicação

ISSN/ISSNe:
0963-8288, 1464-5165

Disability and Rehabilitation  Informa Healthcare

Tipo:
Article
Páginas:
3171-3176
PubMed:
28886676
Link para outro recurso:
www.scopus.com

Citações Recebidas na Web of Science: 11

Citações Recebidas na Scopus: 12

Documentos

  • Não há documentos

Métricas

Filiações mostrar / ocultar

Keywords

  • Chronic kidney failure; dialysis; postural balance; risk assessment; reproducibility of results

Citar a publicação

Partilhar a publicação