Variable Ventilation Associated With Recruitment Maneuver Minimizes Tissue Damage and Pulmonary Inflammation in Anesthetized Lung-Healthy Rats

Data de publicação:

Autores da FMUP

  • Alysson Roncally Silva Carvalho

    Autor

Participantes de fora da FMUP

  • Camilo, Luciana Moises
  • Motta-Ribeiro, Gabriel Casulari
  • de Avila, Mariana Barcellos
  • Santos Cruz Paula, Luis Felipe
  • de Abreu, Mariana Boechat
  • Zin, Walter Araujo

Unidades de investigação

Abstract

BACKGROUND: Recruitment maneuver and positive end-expiratory pressure (PEEP) can be used to counteract intraoperative anesthesia-induced atelectasis. Variable ventilation can stabilize lung mechanics by avoiding the monotonic tidal volume and protect lung parenchyma as tidal recruitment is encompassed within the tidal volume variability. METHODS: Forty-nine (7 per group) male Wistar rats were anesthetized, paralyzed, and mechanically ventilated. A recruitment maneuver followed by stepwise decremental PEEP titration was performed while continuously estimating respiratory system mechanics using recursive least squares. After a new recruitment, animals were ventilated for 2 hours in volume-control with monotonic (VCV) or variable (VV) tidal volumes. PEEP was adjusted at a level corresponding to the minimum elastance or 2 cm H2O above or below this level. Lungs were harvested for histologic analysis (left lung) and cytokines measurement (right lung). Seven animals were euthanized before the first recruitment as controls. RESULTS: A time-dependent increase in respiratory system elastance was observed and significantly minimized by PEEP (P < .001). Variable ventilation attenuated the amount of concentrations of proinflammatory mediators in lung homogenate: neutrophil cytokine-induced neutrophil chemoattractant 1 (VV = 40 +/- 5 and VCV = 57 +/- 8 pg/mg; P < .0001) and interleukin-1 ss (VV = 59 +/- 25 and VCV = 261 +/- 113 pg/mg; P < .0001). Variable ventilation was also associated with lower structural lung parenchyma damage. Significant reductions in air fraction at dorsal and caudal lung regions were observed in all ventilated animals (P < .001). CONCLUSIONS: Variable ventilation was more protective than conventional ventilation within the applied PEEP levels.

Dados da publicação

ISSN/ISSNe:
1526-7598, 0003-2999

Anesthesia and Analgesia  Lippincott Williams and Wilkins Ltd.

Tipo:
Article
Páginas:
784-791
PubMed:
29933268
Link para outro recurso:
www.scopus.com

Citações Recebidas na Web of Science: 8

Citações Recebidas na Scopus: 10

Documentos

  • Não há documentos

Métricas

Filiações mostrar / ocultar

Keywords

  • PROTECTIVE MECHANICAL VENTILATION; TIDAL VOLUMES; INJURY; ATELECTASIS; ANESTHESIA

Citar a publicação

Partilhar a publicação