Liquid- and Air-Filled Catheters without Balloon as an Alternative to the Air-Filled Balloon Catheter for Measurement of Esophageal Pressure

Data de publicação:

Autores da FMUP

  • Alysson Roncally Silva Carvalho

    Autor

Participantes de fora da FMUP

  • Beda, Alessandro
  • Gueldner, Andreas
  • Zin, Walter Araujo
  • Carvalho, Nadja C.
  • Huhle, Robert
  • Giannella-Neto, Antonio
  • Koch, Thea
  • de Abreu, Marcelo Gama

Abstract

Background: Measuring esophageal pressure (P-es) using an air-filled balloon catheter (BC) is the common approach to estimate pleural pressure and related parameters. However, P-es is not routinely measured in mechanically ventilated patients, partly due to technical and practical limitations and difficulties. This study aimed at comparing the conventional BC with two alternative methods for P-es measurement, liquid-filled and air-filled catheters without balloon (LFC and AFC), during mechanical ventilation with and without spontaneous breathing activity. Seven female juvenile pigs (32-42 kg) were anesthetized, orotracheally intubated, and a bundle of an AFC, LFC, and BC was inserted in the esophagus. Controlled and assisted mechanical ventilation were applied with positive end-expiratory pressures of 5 and 15 cmH(2)O, and driving pressures of 10 and 20 cmH(2)O, in supine and lateral decubitus. Main Results: Cardiogenic noise in BC tracings was much larger (up to 25% of total power of P-es signal) than in AFC and LFC (<3%). Lung and chest wall elastance, pressure-time product, inspiratory work of breathing, inspiratory change and end-expiratory value of transpulmonary pressure were estimated. The three catheters allowed detecting similar changes in these parameters between different ventilation settings. However, a non-negligible and significant bias between estimates from BC and those from AFC and LFC was observed in several instances. Conclusions: In anesthetized and mechanically ventilated pigs, the three catheters are equivalent when the aim is to detect changes in P-es and related parameters between different conditions, but possibly not when the absolute value of the estimated parameters is of paramount importance. Due to a better signal-to-noise ratio, and considering its practical advantages in terms of easier calibration and simpler acquisition setup, LFC may prove interesting for clinical use.

Dados da publicação

ISSN/ISSNe:
1932-6203, 1932-6203

PLoS ONE  Public Library of Science

Tipo:
Article
Páginas:
-
PubMed:
25247308
Link para outro recurso:
www.scopus.com

Citações Recebidas na Web of Science: 14

Citações Recebidas na Scopus: 14

Documentos

  • Não há documentos

Métricas

Filiações mostrar / ocultar

Keywords

  • PLEURAL PRESSURE; MECHANICAL VENTILATION; RESPIRATORY-FAILURE; LUNG; SUPINE; CARE

Citar a publicação

Partilhar a publicação