Liquid- and Air-Filled Catheters without Balloon as an Alternative to the Air-Filled Balloon Catheter for Measurement of Esophageal Pressure
Data de publicação:
Autores da FMUP
Participantes de fora da FMUP
- Beda, Alessandro
- Gueldner, Andreas
- Zin, Walter Araujo
- Carvalho, Nadja C.
- Huhle, Robert
- Giannella-Neto, Antonio
- Koch, Thea
- de Abreu, Marcelo Gama
Abstract
Background: Measuring esophageal pressure (P-es) using an air-filled balloon catheter (BC) is the common approach to estimate pleural pressure and related parameters. However, P-es is not routinely measured in mechanically ventilated patients, partly due to technical and practical limitations and difficulties. This study aimed at comparing the conventional BC with two alternative methods for P-es measurement, liquid-filled and air-filled catheters without balloon (LFC and AFC), during mechanical ventilation with and without spontaneous breathing activity. Seven female juvenile pigs (32-42 kg) were anesthetized, orotracheally intubated, and a bundle of an AFC, LFC, and BC was inserted in the esophagus. Controlled and assisted mechanical ventilation were applied with positive end-expiratory pressures of 5 and 15 cmH(2)O, and driving pressures of 10 and 20 cmH(2)O, in supine and lateral decubitus. Main Results: Cardiogenic noise in BC tracings was much larger (up to 25% of total power of P-es signal) than in AFC and LFC (<3%). Lung and chest wall elastance, pressure-time product, inspiratory work of breathing, inspiratory change and end-expiratory value of transpulmonary pressure were estimated. The three catheters allowed detecting similar changes in these parameters between different ventilation settings. However, a non-negligible and significant bias between estimates from BC and those from AFC and LFC was observed in several instances. Conclusions: In anesthetized and mechanically ventilated pigs, the three catheters are equivalent when the aim is to detect changes in P-es and related parameters between different conditions, but possibly not when the absolute value of the estimated parameters is of paramount importance. Due to a better signal-to-noise ratio, and considering its practical advantages in terms of easier calibration and simpler acquisition setup, LFC may prove interesting for clinical use.
Dados da publicação
- ISSN/ISSNe:
- 1932-6203, 1932-6203
- Tipo:
- Article
- Páginas:
- -
- PubMed:
- 25247308
- Link para outro recurso:
- www.scopus.com
PLoS ONE Public Library of Science
Citações Recebidas na Web of Science: 14
Citações Recebidas na Scopus: 14
Documentos
- Não há documentos
Filiações
Keywords
- PLEURAL PRESSURE; MECHANICAL VENTILATION; RESPIRATORY-FAILURE; LUNG; SUPINE; CARE
Citar a publicação
Beda A,Gueldner A,Carvalho AR,Zin WA,Carvalho NC,Huhle R,Giannella A,Koch T,de Abreu MG. Liquid- and Air-Filled Catheters without Balloon as an Alternative to the Air-Filled Balloon Catheter for Measurement of Esophageal Pressure. PLoS ONE. 2014. 9. (9):e103057. IF:3,234. (1).
Portal de investigação
