Effects of Different Levels of Pressure Support on Intra-Individual Breath-to-Breath Variability
Data de publicação:
Autores da FMUP
Participantes de fora da FMUP
- Cruz, Monica R.
- Camilo, Luciana M.
- Paula, Luis Felipe S. C.
- Japiassu, Andre M.
- Beda, Alessandro
- Bozza, Fernando A.
- Medeiros, Denise M.
Abstract
BACKGROUND: Evidence exists that during pressure support ventilation (PSV), the addition of an extrinsic (ie, ventilator-generated) breath-to-breath variability (BBV) of breathing pattern improves respiratory function. If BBV is beneficial per se, choosing the PS level that maximizes it could be considered a valid strategy for conventional PSV. In this study, we evaluated the effect of different PS levels on intrinsic BBV in acutely ill, mechanically ventilated subjects to determine whether a significant relationship exists between PS level and BBV magnitude. METHODS: Fourteen invasively mechanically ventilated subjects were prospectively studied. PS was adjusted at 20 cm H2O and sequentially reduced to 15, 10, and 5 cm H2O. Arterial blood gas analysis and pressure at 0.1 s after the onset of inspiration (P-0.1) were measured at each PS level. Airway and esophageal pressure and air flow were continuously recorded. Peak inspiratory flow, tidal volume (V-T), breathing frequency, and pressure-time product (PTP) were calculated on a breath-by-breath basis. The breathing pattern variability was assessed by the coefficient of variation of the time series of V-T, peak inspiratory flow, and breathing frequency from similar to 60 consecutive breath cycles at each PS level. A general linear model for repeated measures was applied, with PS as an independent factor. A significance level of .05 was considered. RESULTS: Despite a large inter-individual difference in all measured variables (P < .001), the coefficient of variation was as low as 30%, and no significant differences in the coefficient of variation of peak inspiratory flow, breathing frequency, and V-T between PS levels were observed (P > .15). Additionally, a significant increase in P-0.1, PTP, and breathing frequency (P < .01) and a reduction in VT (P < .001) were observed with PS reduction. CONCLUSIONS: Despite a significant increase in spontaneous activity with PS reduction, BBV was not influenced by the PS level and was as low as 30% for all evaluated parameters. (C) 2014 Daedalus Enterprises
Dados da publicação
- ISSN/ISSNe:
- 1943-3654, 0020-1324
- Tipo:
- Article
- Páginas:
- 1888-1894
- PubMed:
- 25118312
- Link para outro recurso:
- www.scopus.com
Respiratory Care Daedalus Enterprises Inc.
Citações Recebidas na Web of Science: 2
Citações Recebidas na Scopus: 3
Documentos
- Não há documentos
Filiações
Keywords
- pressure support ventilation; breath-to-breath variability; patient-ventilator interaction; coefficient of variation
Citar a publicação
Cruz MR,Camilo LM,Paula LFSC,Japiassu AM,Beda A,Carvalho AR,Bozza FA,Medeiros DM. Effects of Different Levels of Pressure Support on Intra-Individual Breath-to-Breath Variability. Respir. Care. 2014. 59. (12):p. 1888-1894. IF:1,838. (3).
Portal de investigação