Effects of Different Levels of Pressure Support on Intra-Individual Breath-to-Breath Variability

Data de publicação:

Autores da FMUP

  • Alysson Roncally Silva Carvalho

    Autor

Participantes de fora da FMUP

  • Cruz, Monica R.
  • Camilo, Luciana M.
  • Paula, Luis Felipe S. C.
  • Japiassu, Andre M.
  • Beda, Alessandro
  • Bozza, Fernando A.
  • Medeiros, Denise M.

Abstract

BACKGROUND: Evidence exists that during pressure support ventilation (PSV), the addition of an extrinsic (ie, ventilator-generated) breath-to-breath variability (BBV) of breathing pattern improves respiratory function. If BBV is beneficial per se, choosing the PS level that maximizes it could be considered a valid strategy for conventional PSV. In this study, we evaluated the effect of different PS levels on intrinsic BBV in acutely ill, mechanically ventilated subjects to determine whether a significant relationship exists between PS level and BBV magnitude. METHODS: Fourteen invasively mechanically ventilated subjects were prospectively studied. PS was adjusted at 20 cm H2O and sequentially reduced to 15, 10, and 5 cm H2O. Arterial blood gas analysis and pressure at 0.1 s after the onset of inspiration (P-0.1) were measured at each PS level. Airway and esophageal pressure and air flow were continuously recorded. Peak inspiratory flow, tidal volume (V-T), breathing frequency, and pressure-time product (PTP) were calculated on a breath-by-breath basis. The breathing pattern variability was assessed by the coefficient of variation of the time series of V-T, peak inspiratory flow, and breathing frequency from similar to 60 consecutive breath cycles at each PS level. A general linear model for repeated measures was applied, with PS as an independent factor. A significance level of .05 was considered. RESULTS: Despite a large inter-individual difference in all measured variables (P < .001), the coefficient of variation was as low as 30%, and no significant differences in the coefficient of variation of peak inspiratory flow, breathing frequency, and V-T between PS levels were observed (P > .15). Additionally, a significant increase in P-0.1, PTP, and breathing frequency (P < .01) and a reduction in VT (P < .001) were observed with PS reduction. CONCLUSIONS: Despite a significant increase in spontaneous activity with PS reduction, BBV was not influenced by the PS level and was as low as 30% for all evaluated parameters. (C) 2014 Daedalus Enterprises

Dados da publicação

ISSN/ISSNe:
1943-3654, 0020-1324

Respiratory Care  Daedalus Enterprises Inc.

Tipo:
Article
Páginas:
1888-1894
PubMed:
25118312
Link para outro recurso:
www.scopus.com

Citações Recebidas na Web of Science: 2

Citações Recebidas na Scopus: 3

Documentos

  • Não há documentos

Métricas

Filiações mostrar / ocultar

Keywords

  • pressure support ventilation; breath-to-breath variability; patient-ventilator interaction; coefficient of variation

Citar a publicação

Partilhar a publicação