The Role of Multidetector Computed Tomography and the Forced Oscillation Technique in Assessing Lung Damage in Adults With Cystic Fibrosis

Data de publicação:

Autores da FMUP

  • Alysson Roncally Silva Carvalho

    Autor

Participantes de fora da FMUP

  • Lacerda, Leticia S.
  • Lopes, Agnaldo J.
  • Guimaraes, Alan R. M.
  • Firmida, Monica C.
  • Castro, Marcos C. S.
  • Mogami, Roberto
  • Melo, Pedro L.

Unidades de investigação

Abstract

BACKGROUND: With increased survival rates and the consequent emergence of an adult population with cystic fibrosis (CF), developing novel tools for periodic evaluations of these patients has become a new challenge. Thus, we sought to determine the contribution of lung-volume quantification using multidetector computed tomography (CT) in adults with CF and to investigate the association between structural changes and functional abnormalities. METHODS: This was a cross-sectional study in which 21 adults with CF and 22 control subjects underwent lung-volume quantification using multidetector CT. Voxel densities were divided into 4 bands: -1,000 to -900 Hounsfield units (HU) (hyperaerated region), -900 to -500 HU (normally aerated region), -500 to -100 HU (poorly aerated region), and -100 to 100 HU (non-aerated region). In addition, all participants performed pulmonary function tests including spirometry, body plethysmography, diffusion capacity for carbon monoxide, and the forced oscillation technique. RESULTS: Adults with CF had more non-aerated regions and poorly aerated regions with lung-volume quantification using multidetector CT than controls. Despite these abnormalities, total lung volume measured by lung-volume quantification using multidetector CT did not differ between subjects and controls. Total lung capacity (TLC) measured by body plethysmography correlated with both total lung volume (r(s) = 0.71, P<.001) and total air volume (r(s) = 0.71, P<.001) as measured with lungvolume quantification using multidetector CT. While the hyperaerated regions correlated with the functional markers of gas retention in the lungs (increased residual volume (RV) and RV/TLC ratio), the poorly aerated regions correlated with the resistive parameters measured by the forced oscillation technique (increased intercept resistance and mean resistance). We also observed a correlation between normally aerated regions and highest pulmonary diffusion values (r(s) = 0.68, P <.001). CONCLUSIONS: In adults with CF, lung-volume quantification using multidetector CT can destimate the lung volumes of compartments with different densities and determine the aerated and non-aerated contents of the lungs; furthermore, lung-volume quantification using multidetector CT is clearly related to pulmonary function parameters. (c) 2018 Daedalus Enterprises

Dados da publicação

ISSN/ISSNe:
1943-3654, 0020-1324

Respiratory Care  Daedalus Enterprises Inc.

Tipo:
Article
Páginas:
430-440
PubMed:
29208759
Link para outro recurso:
www.scopus.com

Citações Recebidas na Web of Science: 7

Citações Recebidas na Scopus: 7

Documentos

  • Não há documentos

Métricas

Filiações mostrar / ocultar

Keywords

  • cystic fibrosis; diagnostic imaging; respiratory function tests; forced oscillation technique

Citar a publicação