Pressure support improves oxygenation and lung protection compared to pressure-controlled ventilation and is further improved by random variation of pressure support
Autores da FMUP
Participantes de fora da FMUP
- Spieth, Peter M.
- Gueldner, Andreas
- Kasper, Michael
- Schubert, Rene
- Carvalho, Nadja C.
- Beda, Alessandro
- Dassow, Constanze
- Uhlig, Stefan
- Koch, Thea
- Pelosi, Paolo
- de Abreu, Marcelo Gama
Abstract
Objectives: To explore whether 1) conventional pressure support ventilation improves lung function and attenuates the pulmonary inflammatory response compared to pressure-controlled ventilation and 2) random variation of pressure support levels (noisy pressure support ventilation) adds further beneficial effects to pressure support ventilation. Design: Three-arm, randomized, experimental study. Setting: University hospital research facility. Subjects: Twenty-four juvenile pigs. Interventions: Acute lung injury was induced by surfactant depletion. Animals were randomly assigned to 6 hrs of mechanical ventilation (n = 8 per group) with either 1) pressure-controlled ventilation, 2) pressure support ventilation, or 3) noisy pressure support ventilation. During noisy pressure support ventilation, the pressure support varied randomly, with values following a normal distribution. In all groups, the driving pressures were set to achieve a mean tidal volume of 6 mL/kg. At the end of experiments, animals were killed and lungs extracted for histologic and biochemical analysis. Measurements and Main Results: Respiratory, gas-exchange, and hemodynamics variables were assessed hourly. The diffuse alveolar damage and the inflammatory response of lungs were quantified. Pressure support ventilation and noisy pressure support ventilation improved gas exchange and were associated with reduced histologic damage and interleukin-6 concentrations in lung tissue compared to pressure-controlled ventilation. Noisy pressure support ventilation further improved gas exchange and decreased the inspiratory effort while reducing alveolar edema and inflammatory infiltration compared to pressure support ventilation. Conclusions: In this model of acute lung injury, pressure support ventilation and noisy pressure support ventilation attenuated pulmonary inflammatory response and improved gas exchange as compared to pressure-controlled ventilation. Noisy pressure support ventilation further improved gas exchange, reduced the inspiratory effort, and attenuated alveolar edema and inflammatory infiltration as compared to conventional pressure support ventilation. (Crit Care Med 2011; 39:746-755)
Dados da publicação
- ISSN/ISSNe:
- 1530-0293, 1530-0293
- Tipo:
- Article
- Páginas:
- 746-755
- PubMed:
- 21263322
- Link para outro recurso:
- www.scopus.com
Critical Care Medicine Lippincott Williams and Wilkins Ltd.
Citações Recebidas na Web of Science: 68
Citações Recebidas na Scopus: 71
Documentos
- Não há documentos
Filiações
Keywords
- mechanical ventilation; acute lung injury; pressure support ventilation; ventilator-associated lung injury; experimental model
Citar a publicação
Spieth PM,Carvalho AR,Gueldner A,Kasper M,Schubert R,Carvalho NC,Beda A,Dassow C,Uhlig S,Koch T,Pelosi P,de Abreu MG. Pressure support improves oxygenation and lung protection compared to pressure-controlled ventilation and is further improved by random variation of pressure support. Crit. Care Med. 2011. 39. (4):p. 746-755. IF:6,330. (1).