Ischemic subglottic damage following a short-time intubation

Data de publicação:

Autores da FMUP

  • Marta João Rodrigues Da Silva

    Autor

  • Jorge Eduardo De Freitas Spratley

    Autor

Participantes de fora da FMUP

  • Aparicio, J
  • Mota, T
  • Ribeiro, A

Abstract

The objective of this study is to report a case of ischemic subglottic damage after a short-time intubation with a large, overinflated endotracheal tube cuff in a child. The study uses individual case report. A 6-year-old boy was admitted to the pediatric intensive care unit after a head trauma intubated with a 5.5-mm inner diameter cuffed endotracheal tube overinflated with 16 ml of air that produced a pressure of more than 120cm H2O. The endotracheal tube cuff pressure produced by inflation was reduced after 4h. The child presented postextubation stridor with subglottic edema. Inappropriate handling of tracheal intubation without accurate measurement of endotracheal tube size and intracuff pressures of endotracheal tubes, can cause airway trauma and place patients at risk. European Journal of Emergency Medicine 15:351-353 (C) 2008 Wolters Kluwer Health vertical bar Lippincott Williams Wilkins.

Dados da publicação

ISSN/ISSNe:
1473-5695, 0969-9546

European Journal of Emergency Medicine  Lippincott Williams and Wilkins Ltd.

Tipo:
Article
Páginas:
351-353
PubMed:
19078841
Link para outro recurso:
www.scopus.com

Citações Recebidas na Web of Science: 10

Citações Recebidas na Scopus: 10

Documentos

  • Não há documentos

Métricas

Filiações

Filiações não disponíveis

Keywords

  • children; cuffed tracheal tubes; head trauma; stridor; subglottic damage

Citar a publicação

Partilhar a publicação