Aortic Valve Calcium Volume Predicts Paravalvular Regurgitation and the Need for Balloon Post-Dilatation after Transcatheter Aortic Valve Implantation

Data de publicação:

Autores da FMUP

  • Carolina Neves Sousa Almeida

    Autor

  • Antonio Jorge Santos Almeida

    Autor

  • Nuno Teodoro V. Reis Bettencourt Sousa

    Autor

  • Francisco Pedro Morais Dias De Almeida Sampaio

    Autor

  • Hernâni Manuel Da Silva Lobo Maia Gonçalves

    Autor

Participantes de fora da FMUP

  • Fonseca, P
  • Figueiredo, B
  • Ferreira, N
  • Braga, P
  • Ribeiro, VG

Abstract

Objective: This study sought to evaluate the impact of aortic valve (AV) and left ventricle outflow tract (LVOT) calcium on paravalvular regurgitation (PVR) and need for balloon post-dilatation (BPD) during transcatheter aortic valve implantation (TAVI). Methods: The overall study population comprised 152 patients. Calcium mass and volume of AV and LVOT were estimated from contrast-enhanced multislice computed tomography imaging, using 3 thresholds for calcium detection [650, 850, and 1,050 Hounsfield units (HU)]. Results: A self-expandable prosthesis was implanted in 67.8% of patients and a balloon-expandable prosthesis in the remaining. Eleven patients required BPD and 82 patients presented post-procedural PVR, which was mild in 44.1% and moderate in 9.9%. The greatest discriminatory value for PVR ? mild was seen for calcium volume using 850 HU threshold, with an area under the curve of 0.72 (95%CI 0.64-0.80, P lt; 0.001) for AV and of 0.63 (95%CI 0.54-0.72, P = 0.008) for LVOT. For 850 HU threshold, the calcium volume cut-off with the highest sum of sensitivity and specificity for PVR was 157 mm3 for AV and 0.6 mm3 for LVOT. In multivariate logistic regression analysis, the presence of AV calcium ?157 mm3 (OR 3.83, 95%CI 1.81-8.10, P lt; 0.001) and ?267 mm3 (OR 11.3, 95%CI 1.2-103.1, P = 0.03) were the only independent predictors of PVR and BPD, respectively. Conclusions: AV calcium volume was an independent predictor of PVR and BPD in patients submitted to TAVI. Our results support a systematic assessment of AV calcium volume to identify patients at increased risk of post-procedural PVR. ? 2015, Wiley Periodicals, Inc.

Dados da publicação

ISSN/ISSNe:
0896-4327, 1540-8183

Journal of Interventional Cardiology  Wiley-Blackwell Publishing Ltd

Tipo:
Article
Páginas:
117-123
PubMed:
26728663
Link para outro recurso:
www.scopus.com

Citações Recebidas na Web of Science: 25

Citações Recebidas na Scopus: 29

Documentos

  • Não há documentos

Métricas

Filiações

Filiações não disponíveis

Keywords

  • COMPUTED-TOMOGRAPHY; CALCIFICATION; ANNULUS; REPLACEMENT; SEVERITY; LOCATION; DEFINITIONS; OUTCOMES; IMPACT; TAVI

Citar a publicação

Partilhar a publicação