Transcatheter aortic valve implantation and requirements of pacing over time

Data de publicação:

Autores da FMUP

  • Nuno Teodoro V. Reis Bettencourt Sousa

    Autor

Participantes de fora da FMUP

  • Pereira, E
  • Ferreira, N
  • Caeiro, D
  • Primo, J
  • Adao, L
  • Oliveira, M
  • Goncalves, H
  • Ribeiro, J
  • Santos, E
  • Leite, D
  • Braga, P
  • Simoes, L
  • Vouga, L
  • Gama, V

Abstract

Background A permanent pacemaker (PPM) implantation is common after transcatheter aortic valve implantation (TAVI). We sought to evaluate requirements of pacing and incidence of pacemaker dependency during the first year after TAVI. Methods From August 2007 until May 2011, 65 patients underwent TAVI with self-expandable prosthesis. Five patients paced at baseline and two procedure-related deaths were excluded. Evaluation of ventricular pacing percentage (VP%) and look for spontaneous rhythm were performed at 3, 6, and 12 months. Results PPM implantation was required in 19/58 patients (33%). Mean VP% decreased between assessments (59% at 3 months, 48% at 6 months, 50% at 12 months), but overall VP% at 1 year was high (57% ? 43%) and most patients were paced ?10% of time. A favorable annulus-to-aorta angle was associated with lower pacing requirements (60% of patients paced ?10% of time vs 10% of patients paced >10% of time presented an angle ?30?, P = 0.039). Pacemaker dependency was established in 27% of patients and could be predicted by the presence of porcelain aorta (odds ratio = 30, confidence interval 95% 1-638, P = 0.029). New postprocedural left bundle branch block (LBBB) had a negative impact on 1-year survival (58% vs 82% in non-LBBB group, P = 0.111). PPM implantation had no impact on 1-year survival. Conclusions One third of patients required PPM after TAVI and full recovery of advanced conduction abnormalities seems unlikely. Unfavorable aortic root orientation may hinder the deployment of the valve and contribute to the continued impairment of the conduction system. Porcelain aorta was a strong predictor of pacemaker dependency. ?2013, The Authors. Journal compilation ?2013 Wiley Periodicals, Inc.

Dados da publicação

ISSN/ISSNe:
0147-8389, 1540-8159

PACE - Pacing and Clinical Electrophysiology  Wiley-Blackwell Publishing Ltd

Tipo:
Article
Páginas:
559-569
PubMed:
23521178
Link para outro recurso:
www.scopus.com

Citações Recebidas na Scopus: 63

Documentos

  • Não há documentos

Métricas

Filiações

Filiações não disponíveis

Keywords

  • Aged; Aged, 80 and over; Aortic Valve; Aortic Valve Stenosis; Arrhythmias, Cardiac; Female; Heart Valve Prosthesis Implantation; Humans; Longitudinal Studies; Male; Retrospective Studies; Treatment Outcome; aged; article; artificial heart; artificial heart pacemaker; female; follow up; heart left bundle branch block; heart pacing; human; major clinical study; male; prediction; retrospective study; survival time; transcatheter aortic valve implantation

Citar a publicação

Partilhar a publicação