Interobserver agreement of EUS elastography in the evaluation of solid pancreatic lesions

Data de publicação:

Autores da FMUP

  • Pedro Filipe Vieira Pimentel Nunes

    Autor

Participantes de fora da FMUP

  • Soares, JB
  • Iglesias Garcia, J
  • Goncalves, B
  • Lindkvist, B
  • Larino Noia, J
  • Bastos, P
  • Caetano, AC
  • Ferreira, A
  • Lopes, L
  • Moutinho Ribeiro, P
  • Enrique Dominguez Munoz, JE

Abstract

Background and Objectives: Previous reports assessing the reproducibility of endoscopic ultrasound elastography (EUS-E) in evaluation of solid pancreatic lesions (SPL) involved only experienced endosonographers. We aimed to assess the interobserver agreement (IOA) of EUS-E in the evaluation of SPL by endoscopists with different levels of experience in EUS and EUS-E. Materials and Methods: A cross-sectional observational multicenter study was designed and included 11 endoscopists who were divided into four groups: Group A (long experience in EUS and EUS-E); Group B (short experience in EUS and EUS-E); Group C (long experience in EUS and no experience in EUS-E); and Group D (no experience in EUS or EUS-E). The observers independently classified the patterns of 60 video sequences of EUS-E, after a 20-min training session. For each group, we calculated IOA (kappa statistic, k) of EUS-E and the diagnostic accuracy of EUS-E for pancreatic malignancy, by comparing the pattern of EUS-E indicative of malignancy (heterogeneous or homogenous blue) with the final diagnosis. Results: The overall IOA was moderate (k = 0.42; 95% confidence interval (CI) 0.33-0.52). The IOA of Group A (k = 0.80; 95% CI 0.65-1.00) was significantly higher than that of Groups B (k = 0.54; 95% CI 0.40-0.71), C (k = 0.54; 95% CI 0.39-0.68), and D (k = 0.28; 95% CI 0.14-0.40). IOA of Groups B and C was not significantly different, but it was significantly higher than that of Group D. The diagnostic accuracy of Group A (area under the curve under summary receiver operating characteristic (AUROC) = 0.83; 95% CI 0.75-0.90) was not significantly different from that of Group B (AUROC = 0.77; 95% CI 0.71-0.83), but it was significantly higher than that of Groups C (AUROC = 0.74; 95% CI 0.67-0.81) and D (AUROC = 0.74; 95% CI 0.67-0.81). No significant difference was seen between Groups B, C, and D for diagnostic accuracy. Conclusion: EUS-E is reproducible in the evaluation of SPL, even between endoscopists with no or limited experience in EUS and/or EUS-E. Reproducibility and diagnostic accuracy increase with experience in EUS and EUS-E.

Dados da publicação

ISSN/ISSNe:
2303-9027, 2226-7190

Endoscopic Ultrasound  Wolters Kluwer Medknow Publications

Tipo:
Article
Páginas:
244-249
PubMed:
26374584
Link para outro recurso:
www.scopus.com

Citações Recebidas na Web of Science: 17

Citações Recebidas na Scopus: 22

Documentos

  • Não há documentos

Métricas

Filiações

Filiações não disponíveis

Keywords

  • Diagnostic accuracy; endoscopic ultrasound elastography; interobserver agreement; reproducibility; solid pancreatic lesions

Citar a publicação

Partilhar a publicação