Hemoglobin Himeji and inconsistent hemoglobin A1c values: A case report
Data de publicação:
Autores da FMUP
Participantes de fora da FMUP
- Guedes, V
- Bettencourt Silva, R
- Queir?s, J
- Esteves, MDL
- Teles, MJ
Abstract
Background: Hemoglobin A1c is used to evaluate the glycemic control in patients with diabetes and is a risk marker for chronic complications of diabetes. Hemoglobin variants are reported to falsely lower or increase hemoglobin A1c test results. We present a case report of a patient with diabetes with discrepancy between fasting plasma glucose and hemoglobin A1c due to the presence of hemoglobin Himeji, a clinically silent and very rare hemoglobinopathy. Case presentation: A 76-year-old white woman, born and living in Portugal, with type 2 diabetes presented to the family physician for a routine visit. She had no active complaints, including history or symptoms of hypoglycemia, and her physical examination was unremarkable. A review of her laboratory data showed fasting plasma glucose of 190 mg/dL and a hemoglobin A1c of 4.1%. The remaining blood test results were clinically insignificant; a further review of her laboratory data over the past 4 years revealed that her fasting plasma glucose had ranged from 130 to 250 mg/dL and hemoglobin A1c was consistently lower than 5%. A study of hemoglobins detected 32.8% of abnormal hemoglobin. Genetic sequencing identified a heterozygous mutation compatible with hemoglobin Himeji (c.422C>A; p.Ala141Asp). We tracked her family (three sons, six grandchildren, and two greatgrandchildren) for the presence of this hemoglobin variant, but none had this hemoglobinopathy. Conclusions: Despite the advantages of hemoglobin A1c in the follow-up and treatment of diabetes, the factors that interfere with its results must be known to ensure a correct estimation of the degree of glycemic control and a proper management of the disease. Therefore, health professionals should suspect the existence of hemoglobin variants when: the hemoglobin A1c value is above 15% or below the lower limit of its reference interval; there is a significant modification in its result coinciding with a change in assay methods; and there is a low correlation between plasma glucose and hemoglobin A1c. In patients with hemoglobin Himeji, alternate ways of monitoring glycemic control (fructosamine or glycated serum albumin) should be used. ? 2017 The Author(s).
Dados da publicação
- ISSN/ISSNe:
- 1752-1947, 1752-1947
- Tipo:
- Article
- Páginas:
- -
- PubMed:
- 28743307
- Link para outro recurso:
- www.scopus.com
Journal of Medical Case Reports BioMed Central Ltd.
Citações Recebidas na Scopus: 4
Documentos
- Não há documentos
Filiações
Filiações não disponíveis
Keywords
- Aged; Biomarkers; Blood Glucose; Diabetes Mellitus, Type 2; Female; Glycated Hemoglobin A; Hemoglobins, Abnormal; Humans; Predictive Value of Tests; glucose; hemoglobin A1c; biological marker; glycosylated hemoglobin; hemoglobin Himeji; hemoglobin variant; aged; Article; case report; Caucasian; diet restriction; electrophoresis; female; gene sequence; glucose blood level; hemoglobin Himeji; hemoglobinopathy; heterozygosity; high performance liquid chromatography; human; non insulin dependent diabetes mellitus; Portugal; priority journal; analysis; blood; genetics; predictive value
Portal de investigação
