Abstract

Purpose: To establish Portuguese Diagnostic Reference Levels (DRLs), for six body fluoroscopy guided interventional procedures (FGIP). Method: A retrospective study was conducted in five interventional departments most representative of Interventional Radiology (IR) practice. Dose values, in terms of air kerma area product (PKA in Gy.cm2), air kerma at the patient entrance reference point (Ka,r in mGy), and exposure parameters (fluoroscopy time (FT) and number of cine runs) were collected. Examinations were selected per procedure (at least 20), according to the anteroposterior and lateral diameter mean value (+/- 5 cm), measured on previous Computed Tomography (CT) examinations. Results: Data of 489 body FGIP show a large variation on dose values per procedure and per department. National DRLs in terms of PKA were 20.2 Gy.cm2 for Percutaneous transhepatic biliary drainage (PTBD), 98.2 Gy.cm2 for Bronchial artery embolisation (BAE), 247.7 Gy.cm2 for Transarterial chemoembolisation (TACE), 331.6 Gy.cm2 for Inferior epigastric arteries embolisation (IEAE), 312.0 Gy.cm2 for Transjugular intrahepatic portosystemic shunt (TIPS) and 19.3 Gy.cm2 for Endovascular treatment of femoral popliteal arteries (ETFPA). Conclusions: This is the first study reporting Interventional Radiology DRLs in Portugal and we propose preliminary national estimates for the six more common body FGIP. The results of this study will be presented and discussed with all Portuguese IR departments, to promote procedures optimisation.

Dados da publicação

ISSN/ISSNe:
1872-7727, 0720-048X

European Journal of Radiology  Elsevier Ireland Ltd

Tipo:
Article
Páginas:
-
Link para outro recurso:
www.scopus.com

Documentos

  • Não há documentos

Métricas

Filiações

Filiações não disponíveis

Keywords

  • Interventional Radiology; Diagnostic Reference Levels; Radiation Protection; Dose values

Campos de estudo

Proyectos asociados

Bioavailability of EPA + DHA Enriched Canned Tuna and Its Acute Effects on Cardiovascular Risk Markers, in Healthy Human Volunteers (FUNCTIONALTUNA) - NCT03742492

Investigador Principal: Luís Filipe Ribeiro de Azevedo

Ensaio Clínico Académico (FUNCTIONALTUNA) . CINTESIS . 2019

Health Tecnology Assessment of Nutrition an Food Productd - The Scientific Evidence Behind Health Claims

Investigador Principal: Luís Filipe Ribeiro de Azevedo

Estudo Clínico Académico . 2020

Comparative effectiveness of opioid therapy for the long term management of chronic non cancer pain

Investigador Principal: Luís Filipe Ribeiro de Azevedo

Estudo Clínico Académico . 2020

Citar a publicação

Partilhar a publicação