Variation in the measurement of DNA damage by comet assay measured by the ECVAG inter-laboratory validation trial
Autores da FMUP
Participantes de fora da FMUP
- Forchhammer, L
- Johansson, C
- Loft, S
- Möller, L
- Godschalk, RWL
- Langie, SAS
- Jones, GDD
- Kwok, RWL
- Collins, AR
- Azqueta, A
- Phillips, DH
- Sozeri, O
- Stepnik, M
- Palus, J
- Vogel, U
- Wallin, H
- Routledge, MN
- Handforth, C
- Allione, A
- Matullo, G
- Costa, S
- Riso, P
- Porrini, M
- Moller, P
Abstract
The comet assay has become a popular method for the assessment of DNA damage in biomonitoring studies and genetic toxicology. However, few studies have addressed the issue of the noted inter-laboratory variability of DNA damage measured by the comet assay. In this study, 12 laboratories analysed the level of DNA damage in monocyte-derived THP-1 cells by either visual classification or computer-aided image analysis of pre-made slides, coded cryopreserved samples of cells and reference standard cells (calibration curve samples). The reference standard samples were irradiated with ionizing radiation (0-10 Gy) and used to construct a calibration curve to calculate the number of lesions per 10(6) base pair. All laboratories detected dose-response relationships in the coded samples irradiated with ionizing radiation (1.5-7 Gy), but there were overt differences in the level of DNA damage reported by the different laboratories as evidenced by an inter-laboratory coefficient of variation (CV) of 47%. Adjustment of the primary comet assay end points by a calibration curve prepared in each laboratory reduced the CV to 28%, a statistically significant reduction (P < 0.05, Levene's test). A large fraction of the inter-laboratory variation originated from differences in image analysis, whereas the intra-laboratory variation was considerably smaller than the variation between laboratories. In summary, adjustment of primary comet assay results by reference standards reduces inter-laboratory variation in the level of DNA damage measured by the alkaline version of the comet assay.
Dados da publicação
- ISSN/ISSNe:
- 1464-3804, 1464-3804
- Tipo:
- Article
- Páginas:
- 113-123
- PubMed:
- 19910383
- Link para outro recurso:
- www.scopus.com
Mutagenesis Oxford University Press
Citações Recebidas na Web of Science: 141
Citações Recebidas na Scopus: 158
Documentos
- Não há documentos
Filiações
Keywords
- Calibration; Cells, Cultured; Comet Assay; Cryopreservation; DNA Damage; DNA-Formamidopyrimidine Glycosylase; Humans; Laboratories; Monocytes; Observer Variation; Radiation, Ionizing; Reference Standards; cesium 137; DNA; article; calibration; comet assay; computer program; cryopreservation; DNA damage; DNA strand breakage; dose response; gamma irradiation; genetic toxicology; human; human cell; image analysis; ionizing radiation; laboratory; measurement; monocyte; priority journal; radiation dose; reference value; scoring system; standard; validation study
Citar a publicação
Forchhammer L,Johansson C,Loft S,Möller L,Godschalk RWL,Langie S,Jones GDD,Kwok RWL,Collins AR,Azqueta A,Phillips DH,Sozeri O,Stepnik M,Palus J,Vogel U,Wallin H,Routledge MN,Handforth C,Allione A,Matullo G,Teixeira JP,Costa S,Riso P,Porrini M,Moller P. Variation in the measurement of DNA damage by comet assay measured by the ECVAG inter-laboratory validation trial. Mutagenesis. 2010. 25. (2):p. 113-123. IF:3,983. (1).
Portal de investigação
