Sensitivity of Myocardial Radiomic Features to Imaging Parameters in Cardiac MR Imaging

Unidades de investigação
Abstract
Background Cardiac magnetic resonance (MR) images are often collected with different imaging parameters, which may impact the calculated values of myocardial radiomic features. Purpose To investigate the sensitivity of myocardial radiomic features to changes in imaging parameters in cardiac MR images. Study Type Prospective. Population A total of 11 healthy participants/five patients. Field Strength/ Sequence A 3 T/cine balanced steady-state free-precession, T-1-weighted spoiled gradient-echo, T-2-weighted turbo spin-echo, and quantitative T-1 and T-2 mapping. For each sequence, the flip angle, in-plane resolution, slice thickness, and parallel imaging technique were varied to study the sensitivity of radiomic features to alterations in imaging parameters. Assessment Myocardial contours were manually delineated by experienced readers, and a total of 1023 radiomic features were extracted using PyRadiomics with 11 image filters and six feature families. Statistical Tests Sensitivity was defined as the standardized mean difference (D effect size), and the robust features were defined at sensitivity < 0.2. Sensitivity analysis was performed on predefined sets of reproducible features. The analysis was performed using the entire cohort of 16 subejcts. Results 64% of radiomic features were robust (sensitivity < 0.2) to changes in any imaging parameter. In qualitative sequences, radiomic features were most sensitive to changes in in-plane spatial resolution (spatial resolution: 0.6 vs. flip angle: 0.19, parallel imaging: 0.18, slice thickness: 0.07; P < 0.01 for all); in quantitative sequences, radiomic features were least sensitive to changes in spatial resolution (spatial resolution: 0.07 vs. slice thickness: 0.16, flip angle: 0.24; P < 0.01 for all). In an individual feature level, no singular feature family/image filter was identified as robust (sensitivity < 0.2) across sequences; however, highly sensitive features were predominantly associated with high-frequency wavelet filters across all sequences (32/50 features). Data Conclusion In cardiac MR, a considerable number of radiomic features are sensitive to changes in sequence parameters. Evidence Level 1 Technical Efficacy Stage 1
Dados da publicação
- ISSN/ISSNe:
- 1522-2586, 1053-1807
- Tipo:
- Article
- Páginas:
- 787-794
- DOI:
- 10.1002/jmri.27581
Journal of Magnetic Resonance Imaging John Wiley & Sons Inc.
Citações Recebidas na Web of Science: 19
Documentos
- Não há documentos
Filiações
Filiações não disponíveis
Keywords
- sensitivity; radiomic features; MR imaging parameters; cardiac MR
Campos de estudo
Proyectos asociados
The predictive value of surgeon's perception during transurethral resection of bladder tumours
Investigador Principal: João Fernando Alturas da Silva
Estudo Clínico Académico (Transurethral) . 2020
Citar a publicação
Jang J,El?Rewaidy H,Ngo LH,Silva J,Csecs I,Rodriguez J,Pierce P,Goddu B,Neisius U,Manning W,Nezafat R-. Sensitivity of Myocardial Radiomic Features to Imaging Parameters in Cardiac MR Imaging. J. Magn. Reson. Imaging. 2021. 54. (3):p. 787-794. IF:5,119. (1).