Non-invasive assessment of cerebral oxygenation: A comparison of retinal and transcranial oximetry

Data de publicação:

Autores da FMUP

  • João Filipe Barbosa Breda

    Autor

Participantes de fora da FMUP

  • Van Keer, K
  • Van Keer, J
  • Nassiri, V
  • De Deyne, C
  • Genbrugge, C
  • Pinto, LA
  • Stalmans, I
  • Vandewalle, E

Unidades de investigação

Abstract

Background To investigate the correlation between cerebral (SO2-transcranial), retinal arterial (SaO(2-retinal)) and venous (SvO(2-retinal)) oxygen saturation as measured by near-infrared spectroscopy (NIRS) and retinal oximetry respectively. Methods Paired retinal and cerebral oxygen saturation measurements were performed in healthy volunteers. Arterial and venous retinal oxygen saturation and diameter were measured using a non-invasive spectrophotometric retinal oximeter. Cerebral oxygen saturation was measured using near-infrared spectroscopy. Correlations between SO2-transcranial and retinal oxygen saturation and diameter measurements were assessed using Pearson correlation coefficients. Lins concordance correlation coefficient (CCC) and Bland-Altman analysis were performed to evaluate the agreement between SO2-transcranial as measured by NIRS and as estimated using a fixed arterial: venous ratio as 0.3 x SaO(2-retinal) + 0.7 x SvO(2-retinal). The individual relative weight of SaO(2-retinal) and SvO(2-retinal) to obtain the measured SO2-transcranial was calculated for all subjects. Results Twenty-one healthy individuals aged 26.4 +/- 2.2 years were analyzed. SO2-transcranial was positively correlated with both SaO(2-retinal) and SvO(2-retinal) (r = 0.44, p = 0.045 and r = 0.43, p = 0.049 respectively) and negatively correlated with retinal venous diameter (r = -0.51, p = 0.017). Estimated SO2-transcranial based on retinal oximetry showed a tolerance interval of (-13.70 to 14.72) and CCC of 0.46 (95% confidence interval: 0.05 to 0.73) with measured SO2-transcranial. The average relative weights of SaO(2-retinal) and SvO(2-retinal) to obtain SO2-transcranial were 0.31 +/- 0.11 and 0.69 +/- 0.11, respectively. Conclusion This is the first study to show the correlation between retinal and cerebral oxygen saturation, measured by NIRS and retinal oximetry. The average relative weight of arterial and venous retinal oxygen saturation to obtain the measured transcranial oxygen saturation as measured by NIRS, approximates the established arterial: venous ratio of 30:70 closely, but shows substantial inter-individual variation. These findings provide a proof of concept for the role of retinal oximetry in evaluating cerebral oxygenation.

Dados da publicação

ISSN/ISSNe:
1932-6203, 1932-6203

PLoS ONE  Public Library of Science

Tipo:
Article
Páginas:
-
PubMed:
29304150

Citações Recebidas na Web of Science: 8

Citações Recebidas na Scopus: 9

Documentos

  • Não há documentos

Métricas

Filiações

Filiações não disponíveis

Keywords

  • NEAR-INFRARED SPECTROSCOPY; BLOOD-FLOW; THERAPEUTIC HYPOTHERMIA; CARDIOPULMONARY BYPASS; VENOUS CONTRIBUTIONS; HEALTHY-SUBJECTS; CARDIAC-SURGERY; SATURATION; ARTERIAL; METABOLISM

Citar a publicação

Partilhar a publicação