Abstract

Background and Aims Capsule endoscopy is a central element in the management of patients with suspected or known Crohns disease. In 2017, PillCam (TM) Crohns Capsule was introduced and demonstrated to have greater accuracy in the evaluation of extension of disease in these patients. Artificial intelligence [AI] is expected to enhance the diagnostic accuracy of capsule endoscopy. This study aimed to develop an AI algorithm for the automatic detection of ulcers and erosions of the small intestine and colon in PillCam (TM) Crohns Capsule images. Methods A total of 8085 PillCam (TM) Crohns Capsule images were extracted between 2017 and 2020, comprising 2855 images of ulcers and 1975 erosions; the remaining images showed normal enteric and colonic mucosa. This pool of images was subsequently split into training and validation datasets. The performance of the network was subsequently assessed in an independent test set. Results The model had an overall sensitivity and specificity of 90.0% and 96.0%, respectively. The precision and accuracy of this model were 97.1% and 92.4%, respectively. In particular, the algorithm detected ulcers with a sensitivity of 83% and specificity of 98%, and erosions with sensitivity and specificity of 91% and 93%, respectively. Conclusion A deep learning model capable of automatically detecting ulcers and erosions in PillCam (TM) Crohns Capsule images was developed for the first time. These findings pave the way for the development of automatic systems for detection of clinically significant lesions, optimizing the diagnostic performance and efficiency of monitoring Crohns disease activity.

Dados da publicação

ISSN/ISSNe:
1873-9946, 1876-4479

JOURNAL OF CROHNS & COLITIS  Oxford University Press

Tipo:
Article
Páginas:
169-172
PubMed:
34228113
Link para outro recurso:
www.scopus.com

Citações Recebidas na Web of Science: 54

Citações Recebidas na Scopus: 66

Documentos

  • Não há documentos

Métricas

Filiações

Filiações não disponíveis

Keywords

  • Capsule Endoscopy; Colon; Crohn Disease; Humans; Intestinal Mucosa; Intestine, Small; Neural Networks, Computer; Pilot Projects; Sensitivity and Specificity; Ulcer; Article; artificial intelligence; colon mucosa; computer simulation; convolutional neural network; Crohn disease; deep learning; detection algorithm; diagnostic accuracy; diagnostic imaging; diagnostic test accuracy study; human; intestine ulcer; performance; pilot study; predictive value; proof of concept; receiver operating characteristic; retrospective study; sensitivity and specificity; stomach erosion; capsule endoscopy; clinical trial; colon; Crohn disease; intestine mucosa; multicenter study; pathology; small intestine; ulcer

Partilhar a publicação