Long-term cryopreservation of potassium bromate positive assay controls for measurement of oxidatively damaged DNA by the Fpg-modified comet assay: results from the hCOMET ring trial
Autores da FMUP
Participantes de fora da FMUP
- Moller, P
- Azqueta, A
- Rodriguez-Garraus, A
- Bakuradze, T
- Richling, E
- Bankoglu, EE
- Stopper, H
- Bastos, VC
- Langie, SAS
- Jensen, A
- Ristori, S
- Scavone, F
- Giovannelli, L
- Wojewodzka, M
- Kruszewski, M
- Valdiglesias, V
- Laffon, B
- Marino, M
- Del Bo', C
- Riso, P
- Zheng, CY
- Shaposhnikov, S
- Collins, A
Unidades de investigação
Abstract
The formamidopyrimidine DNA glycosylase (Fpg)-modified comet assay is widely used for the measurement of oxidatively generated damage to DNA. However, there has not been a recommended long-term positive control for this version of the comet assay. We have investigated potassium bromate as a positive control for the Fpg-modified comet assay because it generates many Fpg-sensitive sites with a little concurrent generation of DNA strand breaks. Eight laboratories used the same procedure for the treatment of monocytic THP-1 cells with potassium bromate (0, 0.5, 1.5, and 4.5 mM) and subsequent cryopreservation in a freezing medium consisting of 50% foetal bovine serum, 40% RPMI-1640 medium, and 10% dimethyl sulphoxide. The samples were analysed by the Fpg-modified comet assay three times over a 3-year period. All laboratories obtained a positive concentration-response relationship in cryopreserved samples (linear regression coefficients ranging from 0.79 to 0.99). However, there was a wide difference in the levels of Fpg-sensitive sites between the laboratory with the lowest (4.2% Tail DNA) and highest (74% Tail DNA) values in THP-1 cells after exposure to 4.5 mM KBrO3. In an attempt to assess sources of inter-laboratory variation in Fpg-sensitive sites, comet images from one experiment in each laboratory were forwarded to a central laboratory for visual scoring. There was high consistency between measurements of %Tail DNA values in each laboratory and the visual score of the same comets done in the central laboratory (r = 0.98, P < 0.001, linear regression). In conclusion, the results show that potassium bromate is a suitable positive comet assay control.
Dados da publicação
- ISSN/ISSNe:
- 1464-3804, 1464-3804
- Tipo:
- Article
- Páginas:
- 264-272
- PubMed:
- 37357815
Mutagenesis Oxford University Press
Citações Recebidas na Web of Science: 13
Citações Recebidas na Scopus: 15
Documentos
- Não há documentos
Portal de investigação