Long-term cryopreservation of potassium bromate positive assay controls for measurement of oxidatively damaged DNA by the Fpg-modified comet assay: results from the hCOMET ring trial

Data de publicação: Data Ahead of Print:

Autores da FMUP

  • Carla Susana Fernandes Da Costa De Araújo

    Autor

  • Sandra Marques Da Costa

    Autor

  • João Paulo Fernandes Teixeira

    Autor

Participantes de fora da FMUP

  • Moller, P
  • Azqueta, A
  • Rodriguez-Garraus, A
  • Bakuradze, T
  • Richling, E
  • Bankoglu, EE
  • Stopper, H
  • Bastos, VC
  • Langie, SAS
  • Jensen, A
  • Ristori, S
  • Scavone, F
  • Giovannelli, L
  • Wojewodzka, M
  • Kruszewski, M
  • Valdiglesias, V
  • Laffon, B
  • Marino, M
  • Del Bo', C
  • Riso, P
  • Zheng, CY
  • Shaposhnikov, S
  • Collins, A

Unidades de investigação

Abstract

The formamidopyrimidine DNA glycosylase (Fpg)-modified comet assay is widely used for the measurement of oxidatively generated damage to DNA. However, there has not been a recommended long-term positive control for this version of the comet assay. We have investigated potassium bromate as a positive control for the Fpg-modified comet assay because it generates many Fpg-sensitive sites with a little concurrent generation of DNA strand breaks. Eight laboratories used the same procedure for the treatment of monocytic THP-1 cells with potassium bromate (0, 0.5, 1.5, and 4.5 mM) and subsequent cryopreservation in a freezing medium consisting of 50% foetal bovine serum, 40% RPMI-1640 medium, and 10% dimethyl sulphoxide. The samples were analysed by the Fpg-modified comet assay three times over a 3-year period. All laboratories obtained a positive concentration-response relationship in cryopreserved samples (linear regression coefficients ranging from 0.79 to 0.99). However, there was a wide difference in the levels of Fpg-sensitive sites between the laboratory with the lowest (4.2% Tail DNA) and highest (74% Tail DNA) values in THP-1 cells after exposure to 4.5 mM KBrO3. In an attempt to assess sources of inter-laboratory variation in Fpg-sensitive sites, comet images from one experiment in each laboratory were forwarded to a central laboratory for visual scoring. There was high consistency between measurements of %Tail DNA values in each laboratory and the visual score of the same comets done in the central laboratory (r = 0.98, P < 0.001, linear regression). In conclusion, the results show that potassium bromate is a suitable positive comet assay control.

Dados da publicação

ISSN/ISSNe:
1464-3804, 1464-3804

Mutagenesis  Oxford University Press

Tipo:
Article
Páginas:
264-272
PubMed:
37357815

Citações Recebidas na Web of Science: 13

Citações Recebidas na Scopus: 15

Documentos

  • Não há documentos

Métricas

Filiações mostrar / ocultar

Partilhar a publicação