Reference standards for gene fusion molecular assays on cytological samples: an international validation study.

Data de publicação: Data Ahead of Print:

Autores da FMUP

Participantes de fora da FMUP

  • Malapelle U
  • Pepe F
  • Pisapia P
  • Altimari A
  • Bellevicine C
  • Brunnström H
  • Bruno R
  • Büttner R
  • Cirnes L
  • De Andrea CE
  • de Biase D
  • Dumur CI
  • Ericson Lindquist K
  • Fontanini G
  • Gautiero E
  • Gentien D
  • Hofman P
  • Hofman V
  • Iaccarino A
  • Lozano MD
  • Mayo-de-Las-Casas C
  • Merkelbach-Bruse S
  • Pagni F
  • Roman R
  • Siemanowski J
  • Roy-Chowdhuri S
  • Tallini G
  • Tresserra F
  • Vander Borght S
  • Vielh P
  • Vigliar E
  • Vita GAC
  • Weynand B
  • Rosell R
  • Molina Vila MA
  • Troncone G

Unidades de investigação

Abstract

AIMS: Gene fusions assays are key for personalised treatments of advanced human cancers. Their implementation on cytological material requires a preliminary validation that may make use of cell line slides mimicking cytological samples. In this international multi-institutional study, gene fusion reference standards were developed and validated. METHODS: Cell lines harbouring EML4(13)-ALK(20) and SLC34A2(4)-ROS1(32) gene fusions were adopted to prepare reference standards. Eight laboratories (five adopting amplicon-based and three hybridisation-based platforms) received, at different dilution points two sets of slides (slide A 50.0%, slide B 25.0%, slide C 12.5% and slide D wild type) stained by Papanicolaou (Pap) and May Grunwald Giemsa (MGG). Analysis was carried out on a total of 64 slides. RESULTS: Four (50.0%) out of eight laboratories reported results on all slides and dilution points. While 12 (37.5%) out of 32 MGG slides were inadequate, 27 (84.4%) out of 32 Pap slides produced libraries adequate for variant calling. The laboratories using hybridisation-based platforms showed the highest rate of inadequate results (13/24 slides, 54.2%). Conversely, only 10.0% (4/40 slides) of inadequate results were reported by laboratories adopting amplicon-based platforms. CONCLUSIONS: Reference standards in cytological format yield better results when Pap staining and processed by amplicon-based assays. Further investigation is required to optimise these standards for MGG stained cells and for hybridisation-based approaches.

© Author(s) (or their employer(s)) 2023. No commercial re-use. See rights and permissions. Published by BMJ.

Dados da publicação

ISSN/ISSNe:
0021-9746, 1472-4146

Journal of Clinical Pathology  BMJ Publishing Group

Tipo:
Article
Páginas:
47-52
PubMed:
34429353
Link para outro recurso:
www.scopus.com

Citações Recebidas na Web of Science: 17

Citações Recebidas na Scopus: 21

Documentos

  • Não há documentos

Métricas

Filiações mostrar / ocultar

Keywords

  • cytological techniques; molecular; molecular biology; pathology

Citar a publicação

Partilhar a publicação